Every 50 Hours — Handle of Locking
Mechanism
Lubricate with grease.
Every 500 Hours — Gear Case
Change the oil after every 500 hours of operation or at the
end of each harvesting season.
Raise pickup slightly so that it is horizontal, and check oil
level in gear case (A). Oil level is correct when it reaches
the bottom edge of oil level plug (B).
IMPORTANT: Do not overfill gear case (A) as this will
result in overheating and oil leakage.
A—Gear Case - 0.4 L (0.11 US.
gal)
Every 500 Hours — Angle Drive
Change the oil after every 500 hours of operation or at the
end of each harvesting season.
IMPORTANT: Do not overfill gear case (A) as this will
result in overheating and oil leakage.
A—Angle Drive - 1.5 L (0.4 U.S.
gal.)