Window Re-Installation & Checking - Valor G3.5 Installation Manual

With autofire, direct vent insert gas fireplace, natural gas, propane gas
Table of Contents

Advertisement

Installation
Refi t and Check Window
1. Place the window in its bottom railing and push
its top against the fi rebox. Ensure to remove any
particles in the railing before installing the window.
Window
frame
Bottom
railing
2. While you hold it, hook the side levers into the
window tabs.
3. Pull out the top of the window and release it to
ensure the springs return it.
4. Apply fi rm hand pressure around the window frame
to ensure the window is sealed tight against the
fi rebox.
5. If the Hot Glass Warning plate has been removed
from the front lower corner of the window, reinstall
it by sliding it between the glass and the frame as
indicated below.
Hot Glass Plate
Window Re-Installation & Checking
WARNING
The window unit must be correctly
installed, fastened and sealed after
servicing or serious bodily injury and/or
damage to the appliance may result.
To ensure a safe operation:
Double-check that the bottom of the
window frame is correctly installed in
the bottom support railing;
Verify that the levers are hooked
properly to the window tabs then;
Pull out the top of the window and
release it to insure the springs return it;
Ensure the window is sealed before
operation.
WARNING
Failure to install the window correctly can:
• Leak carbon monoxide.
• Affect the performance of the fireplace.
• Damage components.
• Cause overheating resulting in dangerous
conditions.
Damage caused by incorrect window
installation is not covered by the Valor
Warranty.