1.5.2

Tilting and handling

1.5.3

Sharp edges

1.5.4

Electric hazards

1.5.5

Installation safety

2 2 -O CT -19
WARNING
Heavy equipment
The Terra DC Wallbox weighs about 70 kg. Handling Instruc-
tions:
1. Consider always two people to install and hang a Terra DC
Wallbox to a wall.
2. Do not drop the Terra DC Wallbox.
WARNING
Sharp metal edges
There could be sharp metal edges inside the Terra DC Wall-
box. It is recommended to wear mash protecting gloves
when working inside the charger.
DANGER
Hazardous voltage
The Terra DC Wallbox contains conductors under hazardous
electrical voltages. The grid terminals on the internal DIN rail
may carry hazardous voltages, even if all circuit breakers are
switched off.
DANGER
Hazardous voltage
Instructions:
1. Always switch off the external group switch upstream
(Main breaker, RCD and disconnector or) before performing
any installation, disassembly, repair or replacement of com-
ponents.
2. Do a voltage check and make sure that the electrical pow-
er is disconnected from the system.
3. Only ABB certified technicians are permitted to commis-
sion the Terra DC Wallbox.
4. When the system is in an open or dangerous condition, do
not allow unqualified persons to go near it. Instruct and
warn people about the potential harmful high voltages.
5. The installation and maintenance personnel must supply
their own lighting equipment, since the Terra DC Wallbox
has no lights inside the cabinet.
6. Always connect the Protective Earth (PE) first, before con-
necting the neutral (N) and Phase (P) wiring.
7. Correctly fixate the enclosure of the Terra DC Wallbox af-
ter installation or service operations.
T ERRA D C WA LLBO X