Detailed Setup and Configuration
The State Indicator (B) for each function will light for the duration of the closure on GPIs. For GPOs, it will light for the
duration of an active event.
Certain GPIs have selectable Parameters (C) associated with them. For example, selecting a "Recall Profile" function will
present a dropdown menu to select the desired profile.
Likewise, some GPOs have user-defined Parameters (E) as well. Choosing one of the "Loudness Above Target Range" or
"Loudness Below Target Range" functions will display the following parameters:
Measurement determines the integration time used to measure the over/under loudness status
♦
Threshold determines how far the loudness readings must deviate from the target in dB
♦
On Time is the length of time (in seconds) that loudness levels must stay above/below the threshold in order to trigger
♦
the GPO
Off Time is the length of time (in seconds) that loudness levels must return and remain within tolerance before the GPO
♦
is cleared
Figure 6-6 – GPI/O menu