Detailed Setup and Configuration
The AES-3 output is configured in the AES-3 sub-menu and in much the same way as SDI and AES67 outputs.
Click on the AES-3 sub-menu of the "I/O" menu (A). Use the dropdown menu (C) of the "AES-3 Out" routing section to
select which audio gets routed to the AES-3 output. Sources may include processed audio as well as available SDI, AES67, and
AES-3 inputs.
As with the other outputs, you can customize the name of the AES-3 input pair to make identifying the sources easier. Click
inside the Label field (B) of the "AES-3 In" section, type a name, then click the green checkmark to save your changes.
The Input SRC (D) is enabled by default. If the AES-3 input is your clock reference, disabling the SRC will reduce latency
slightly. If there are any anticipated reference clock changes (either intentional or unplanned) it is safer to leave it enabled.
GPI/O
ARC features five GPI and five GPO functions through its rear panel DB-15 connector, activated by a momentary contact
closure.
GPI Functions (A) include:
None
♦
Reboot/Reset Unit
♦
Hardware (Relay) Bypass
♦
Reset All Input Loudness Meters
♦
Reset All Output Loudness Meters
♦
Reset All Loudness Meters
♦
Recall Profile (PGM 1)
♦
GPO Functions (D) include:
GPI Passthrough
♦
Power Supply 1 Up
♦
Power Supply 2 Up
♦
Power Supply 1 Down
♦
Power Supply 2 Down
♦
Unit Resetting
♦
Unit Rebooting
♦
Unit Powering Down
♦
Unit Above Temperature
♦
Unit Bypass (Relay Bypass) Active
♦
Change in Reference
♦
Primary Reference Clock is Lost
♦
Reset Program 1 Input Loudness Meter
♦
Reset Program 1 Output Loudness Meter
♦
Bypass Program 1 Processing
♦
Recall Profile (PGM 2)
♦
Reset Program 2 Input Loudness Meter
♦
Reset Program 2 Output Loudness Meter
♦
Bypass Program 2 Processing
♦
Secondary Reference Clock is Lost
♦
Primary Reference Clock is Active
♦
Secondary Reference Clock is Active
♦
Internal Reference is Active
♦
Program 1 Loudness Above Target Range
♦
Program 1 Loudness Below Target Range
♦
Program 1 APTO Processor Bypassed
♦
Program 1 Output Loudness Meter Reset
♦
Program 2 Loudness Above Target Range
♦
Program 2 Loudness Below Target Range
♦
Program 2 APTO Processor Bypassed
♦
Program 2 Loudness Meter Reset
♦
Chapter 6 |
34