Remote User Interface
To use a fixed IP address, first click the Edit button (A) to unlock the settings for each Ethernet port. Click on the Use DHCP
button (B) to disable DHCP. The text of the NET Address, Net Mask, and Gateway fields (D), which is grayed out when
DHCP is enabled, will turn white and become editable. Once the information is entered, click on the Apply button (or the
Cancel button to back out without making any changes). Verify that you have a good network connection by looking for a green
dot and the word Active in the status window.
Setup is identical for both the Control and AES67 ports.
If either of the two Ethernet ports will not be used, do not connect the unused port to a network switch, and set "Use DHCP" to
"Yes" for the unused port.
Sync, QoS, and PTP Menu
As explained in Chapter 3, whenever ARC is set up to use AES67 audio either on the input, the output, or both, it must be slaved
to an external PTP clock for reference.
Important!
At this time, ARC mustbe slaved to an external PTP clock if AES67 streams are used for audio input, output,
or both. Additional PTP-related settings are grayed out and reserved for future use.
The Slave Only button (A) must be enabled and the Domain Number must be set for the correct PTP domain.
Valid values are 0 – 127. The AES67 PTP profile uses 0; the SMPTE PTP profile uses 127.