Check the fuse capacities of power supply devices.
Subrack Type
OSN 9560
OSN 3500
OSN 7500
Measure the voltage between NEG (-) and RTN (+) on the DC power distribution box.
Voltage Range
CAUTION
Do not power on the equipment if the power supply voltage does not meet the requirement.
Checking Fiber Attenuation
CAUTION
Wear protective glasses or goggles when you look directly at optical ports to check fiber attenuation.
1
Optical power
P1
Optical power
meter
1
Measure the output power of the
optical source.
NOTE
If the difference between P2 and P1 is less than 1 dB, the fiber connection is normal. If the difference is larger than
1 dB, clean the fiber. If the difference is still larger than 1 dB after cleaning, replace the fiber.
NOTE
Setting the wavelength of the light source to approximately 1550 nm and the wavelength range of the optical power
meter to 1550 nm is recommended. After the equipment is powered on, you can also use a board that can
generate optical signals as a light source.
Maximum Power
Consumption
4800 W
720 W (standard subrack)
1100 W (enhanced subrack)
1100 W
If -48 V Power Is
Used
-40 V to -57.6 V
Short fiber
Stable light
source
42
Fuse Capacity
60 A
20 A
32 A
32 A
If -60 V Power Is
Used
-48 V to -72 V
2
External fiber
ODF
Optical power
P2
2
Measure the output power after the signal
traverses the fiber to be checked.
Fiber to be checked