5 Installation
Connecting the L-406 to the protective earth conductor
1. If necessary, attach a suitable cable lug to the protective earth conductor.
2. Use the M4 screw (together with the flat and lock washers) to attach the cable lug of
the protective earth conductor to the threaded hole in the L-406 as shown in the profile
view.
3. Tighten the M4 screw with a torque of 1.2 Nm to 1.5 Nm.
4. Make sure that the contact resistance at all connection points relevant for connecting
the protective earth conductor is <0.1 Ω at 25 A.
5.4

Fixing the Load to the L-406

NOTICE
Impermissibly high load on the positioner!
An impermissible high load impairs the motion of the motion platform and can damage the
positioner.
 For mounting type and mass of the load, pay attention to the maximum permissible forces
that are allowed to act on the motion platform according to the specification (p. 43).
NOTICE
Excessively long screws!
Screws and locating pins inserted too deeply can damage the lower positioner.
 Pay attention to the depth of the mounting holes in the motion platform (p. 46) of the
lower positioner.
 Only use screws and locating pins of the correct length for the respective mounting holes.
Requirements
 You have read and understood the general notes on installation (p. 15).
 You have mounted the L-406 onto an underlying surface (p. 16) properly.
 The L-406 is not connected to the controller.
 You have prepared the load so that it can be fixed to the mounting holes in the
platform:
20
Version: 1.1.0
The gap between the center of gravity of the load and the center of the platform is
as small as possible in all directions.
At least two points are provided for fixing the load to the platform (ideally: three or
four attachment points).