Table 4-9 Datacorder Pre-Trip Result Records - Carrier Transicold 69NT40-561-001 Operation And Service Manual

Container refrigeration units
Hide thumbs Also See for Transicold 69NT40-561-001:
Table of Contents

Advertisement

Test
Title
1-0
Heater On
1-1
Heater Off
2-0
Condenser Fan On
2-1
Condenser Fan Off
3-0
Low Speed Evaporator Fan On
3-1
Low Speed Evaporator Fan Off
4-0
High Speed Evaporator Fan On Pass / Fail / Skip Result, Change in currents for Phase A, B and C
4-1
High Speed Evaporator Fan Off Pass / Fail / Skip Result, Change in currents for Phase A, B and C
5-0
Supply / Return Probe Test
5-1
Secondary Supply Probe
(SRS) Test
5-2
Secondary Return Probe
(RRS) Test
6-0
Discharge Thermistor Test
6-1
Suction Thermistor Test
6-2
Discharge Pressure
Transducer Test
6-3
Suction Pressure
Transducer Test
6-4
Compressor Current Draw Test Pass / Fail / Skip
6-5
Compressor Leak Test
6-6
Economizer Valve Test
6-7
Digital Unloader Valve Test
6-9
Liquid Injection Valve Test
(If equipped)
6-10
Electronic Expansion Valve Test Pass / Fail / Skip
7-0
High Pressure Switch Closed
7-1
High Pressure Switch Open
8-0
Perishable Mode Heat Test
8-1
Perishable Mode Pulldown Test Pass / Fail / Skip Result, STS, time it takes to pull down to 0°C (32°F)
8-2
Perishable Mode Maintain Test
9-0
Defrost Test
10-0
Frozen Mode Heat Test
10-1
Frozen Mode Pulldown Test
10-2
Frozen Mode Maintain Test
T-340
Table 4–9 DataCORDER Pre-trip Result Records
Data
Pass / Fail / Skip Result, Change in currents for Phase A, B and C
Pass / Fail / Skip Result, Change in currents for Phase A, B and C
Pass / Fail / Skip Result, Water pressure switch (WPS) - Open /
Closed; Change in currents for Phase A, B and C
Pass / Fail / Skip Result, Change in currents for Phase A, B and C
Pass / Fail / Skip Result, Change in currents for Phase A, B and C
Pass / Fail / Skip Result, Change in currents for Phase A, B and C
Pass / Fail / Skip Result, STS, RTS, SRS and RRS
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens
Pass / Fail / Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
Pass / Fail / Skip Result, STS, time it takes to heat to 16°C (60°F)
Pass / Fail / Skip Result, Averaged DataCORDER supply tempera-
ture (SRS) over last recording interval.
Pass / Fail / Skip Result, DTS reading at end of test, line voltage, line
frequency, time in defrost.
Pass / Fail / Skip Result, STS, time unit is in heat.
Pass / Fail / Skip Result, STS, time to pull down unit to -17.8°C (0°F).
Pass / Fail / Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.
4–54