Code
Title
Display Only Functions - Cd38 through Cd40 are display only functions.
Cd38
Secondary Supply
Temperature Sensor
Cd39
Secondary Return
Temperature Sensor
Cd40
Container
Identification
Number
Cd41
Valve Override
Configurable Functions - Cd43 is a user-selectable function. The operator can change the value of this function
to meet the operational needs of the container.
Cd43
eAutoFresh Mode
Table 4–5 Controller Function Codes
Description
Cd38 will display the current supply recorder sensor (SRS) reading for units con-
figured for four probes. If the unit is configured with a DataCORDER, Cd38 will
display "-----." If the DataCORDER suffers a failure, (AL55) Cd38 will display the
supply recorder sensor reading.
Cd39 will display the current return recorder sensor (RRS) reading for units config-
ured for four probes. If the unit is configured with a DataCORDER, Cd39 will display
"-----." If the DataCORDER suffers a failure, (AL55) Cd39 will display the return re-
corder sensor reading.
If a valid container id exists, the default display for Cd40 will be "cd40_XXXXX"
where "XXXXX" is the 5th character through the 9th character of the container id.
Pressing the ENTER key on Cd40 will display "id_YYYYYYY" where "YYYYYYY"
is the 5th character to the 11th character of the container id.
If no valid container id exists or the container id is blank, the default display will have
Cd40 on the left display and the right display will alternate between "_nEEd" and
"___id". Pressing the ENTER key while on Cd40 in the state will prompt the Set Id
Interface.
On start up if the container id is not valid, Cd40 will be brought up on the display for
the first minute of power up. This can be left by either entering a container id or leav-
ing the code select normally.
Cd40 is configured at commissioning to read a valid container identification num-
ber. The reading will not display alpha characters; only the numeric portion of the
number will display.
SERVICE FUNCTION: This code is used for troubleshooting, and allows manual
positioning of the economizer solenoid valve, electronic expansion valve, and
digital unloader valve. Provides readings such as: Percent Capacity, EEV, Ca-
pacity Mode, LIV and DUV. Refer to
Cd43 is a user selectable mode of operation that allows the opening and closing
of a mechanical air vent door via a stepper motor. These selection modes are as
follows:
OFF - Air makeup vent will remain closed.
USER - Allows for manual selection of the setting.
DELAY - The opening of the door is based on selected time, return temperature
and flow rate (percent opened).
gASLM - The opening is based percent open and CO
(LM). This selection is only active if the unit has a CO
TEST / CAL (CO
sensor option units only) - The door will fully open and close
2
to allow the user to inspect its operation. If CAL is selected, the controller will
zero calibrate the CO
sensor input.
2
If the unit is not configured with AutoFresh, the Cd43 will display "----"
Section 5.4.3
Refer to
for description of operational parameters.
4–29
Section 7.21
for operating instructions.