d. Records DataCORDER and temperature control software generated data and events as follows:
Container ID Change
Software Upgrades
Alarm Activity
Battery Low (battery pack)
Data Retrieval
Defrost Start and End
Dehumidification Start and End
Power Loss (with and without battery pack)
Power Up (with and without battery pack)
Remote Probe Temperatures in the Container (USDA Cold treatment and Cargo probe recording)
Return Air Temperature
Set Point Change
Supply Air Temperature
Real Time Clock Battery (Internal) Replacement
Real Time Clock Modification
Trip Start
ISO Trip Header (When entered via Interrogation program)
Economy Mode Start and End
"Auto 1/Auto 2/Auto 3" Pre-trip Start and End
Bulb Mode Start
Bulb Mode Changes
Bulb Mode End
USDA Trip Comment
Humidification Start and End
USDA Probe Calibration
Fresh Air Vent Position
4.8.2

DataCORDER Software

The DataCORDER Software is subdivided into Operational Software, Configuration Software, and the Data Memory.
a. Operational Software
The Operational Software reads and interprets inputs for use by the Configuration Software. The inputs are labeled
Function Codes. Controller functions (see
data or stored data. To access these codes, do the following:
1. Press the ALT. MODE and CODE SELECT keys.
2. Press an Arrow key until the left window displays the desired code number. The right window will display the
value of this item for five seconds before returning to the normal display mode.
3. If a longer display time is desired, press the ENTER key to extend the display time to 30 seconds.
b. Configuration Software
The configuration software controls the recording and alarm functions of the DataCORDER. Reprogramming to the
factory-installed configuration is achieved via a configuration card. Changes to the unit DataCORDER configura-
tion may be made using the DataLINE interrogation software. A list of configuration variables is provided in
4–2. Descriptions of DataCORDER operation for each variable setting are provided in the following paragraphs.
Table
4–8) which the operator may access to examine the current input
4–17
Table
T-340