Code
Title
Configurable Functions - Cd50 through Cd53 are user-selectable functions. The operator can change the value
of these functions to meet the operational needs of the container.
Cd50
CCPC Disabled
Cd51
Automatic Cold
Treatment
Parameter Selection
T-340
Table 4–5 Controller Function Codes
Description
"OFF" = disabled.
"On" = enabled.
"SEtPt" = suspended by setpoint too low.
"CAHUM" = suspended by CA or humidity control.
"ACt" = suspended by ACT active.
"FAIL" = all return temperature probe failure for CCPC.
"PrtrP" = pretrip active.
"C LIM" = suspended by cool limit logic.
"PULL" = pulldown active.
"ALArM " = suspended by shutdown alarm
Press the ENTER key, Arrow keys, and then ENTER to select "OFF" or "On".
If "On" is selected, CCPC operation may be suspended as indicated by one of
the suspension codes listed above. If CCPC is not "OFF" and is not suspended,
"On" will be displayed.
ACT-mode:
Cd51 increments of (1 day)_(1hr), Display: default "0_0 "
"done" mm-dd this will be display is ACT has completed
"ACt" value "On" "OFF" or "----"Display /Select: default "OFF"
"trEAt" value °C / °F on 0.1 degree increments Display/Select: default "0.0°C"
"DAyS" value "0 - 99" increments of 1 Display/Select: default "0"
"ProbE" value Probe positions ex '1 2 _ 4' '1 _ 3 _' Display: default "---- "
"SPnEW" value °C / °F on 0.1° increments Display/Select: default "10.0°C "
Initially Cd51 will display current countdown timer increments of (1 day)_(1hr),
default "0_0
Pressing the ENTER key will take the interface down into a hierarchy of param-
eter selection menus (act, treat, days, probe and spnew setting).
Pressing the ENTER key in any of the parameter selection menus commits to
selection of the currently displayed parameter and causes the interface to de-
scend into the next parameter selection menu. All parameter selection menus al-
ternate between a blank display and the current selection in the right hand
display.
Pressing the CODE SELECT key in a selection menu cancels the current selec-
tion activity and ascends back up to the next higher selection menu (or to Cd51
display mode if that is the next higher).
If the operator does not press any key for five seconds the interface reverts to
normal system display and the current selection menu is cancelled, but any pre-
viously committed changes are retained.
Available parameters and parameter ranges are a function of configuration op-
tions and previously selected parameters as indicated above.
Parameter with the exception of "Act" may not be altered if Cd51 is re-entered if
"Act" is "On". When ACT has completed including reaching the new setpoint "do-
ne" on the left display and the MONTH DAY of completion on the right display
will be displayed as the second entry in the menu. Turning ACT off clears this
entry. This action also resets Cd51 to initial time remaining. ACT must then be
turned on to view or modify the additional parameters.
Whenever any auto Pre-trip test or Trip Start is initiated, ACT mode goes to OFF.
4–32