Operating specifications
The following table summarizes the operating specifications of the controller unit.
Size (with front panel and without
mounting rails)
•
Depth: 63.5 cm (25 in.)
•
Height: 17.45 cm (6.87 in.)
•
Width: 44.45 cm (17.5 in.)
Weight
•
Typical controller unit fully
configured: 38.6 kg (85 lbs)
Electrical input
•
Sine-wave input (50 to 60 Hz) is
required
•
Input voltage:
–
Low range:
-
Minimum: 90 V ac
-
Maximum: 132 V ac
–
High range:
-
Minimum: 198 V ac
-
Maximum: 262 V ac
–
Input kilovolt-amperes (kVA)
approximately: 0.214 kVA
Table 1: RAID controller unit specifications
Environment
•
Air temperature:
–
Controller unit on:
º
º
to 35
C
10
º
º
(50
to 95
Altitude: 0 to 914 m (3000 ft)
–
Controller unit on
º
º
to 32
C
10
º
º
(50
to 90
Altitude: 914 m (3000 ft) to
2133 m (7000 ft)
•
Humidity
–
%
%
10
to 80
Accoustical noise emissions values:
For typical system configurations:
•
•
•
F)
•
These levels are measured in
controlled acoustical environments
F)
according to ISO 7779 and are
reported in accordance with ISO 9296.
The declared sound power levels
indicate an upper limit, below which a
large portion of machines operate.
Sound pressure levels in your location
might exceed the average 1-meter
values stated because of room
reflections and other nearby noise.
Sound power (idling): 6.5 bels
Sound power (operating): 6.5 bels
Sound pressure (idling): 49 dBA
Sound pressure (operating): 49 dBA
Chapter 1. Getting started