Settings and Adjustments
Entry
OPTION RELAY CONTROL Select Enable / Disable for
Relay Output 2
FUNCTION
Configuring on the station
Description
RANGE
Select the Output Time
(TIMER)
Range for relay output if
"FUNCTION (→page 85)"
is set to "Door Release".
Option Relay Control when
using the speed dial of IXG-
MK to control the output.
This can be controlled as
optional relay if set to
"Enable." If "Option Relay
Control Authentication Key"
is not configured, this will
not operate even if set to
"Enable."
Select the function of the
Relay Output.
86
Settings
• 200 to 2000 msec:
400 msec
Select this to set a
time between 200 and
2000 msec (by 200
msec). Enter the time
in "TIMER."
• 3 to 600 sec: Select
this to set a time
between 3 and 600
sec (by 1 sec). Enter
the time in "TIMER."
• Enable
Disable
• Disable
• None
None
• Status Output: Relay
Output during the
status. The details
setting can be set in
"How to configure the
Status Output
(→page
106)".
• Door Release: Relay
output when door
release is activated or,
entering the
authentication key
using keypad of the
station or the VoIP
Phone. Refer to
"How
to configure Door
Release settings
(→page 107)"
for
information on how to
configure this. If a door
release operation is
performed on another
station, the electrical
lock will not be
released unless
"Code" is configured.
Be sure to configure
"Code" via Web
configuration or the
IXG Support Tool.
Default values