3.5.3 AC Plug Assembly

CAUTION: Machine And Equipment Damage May Occur!
- Please make sure to use the proper size AC cable.
- Please choose the terminals as shown below for wires crimping.
- Failed to follow these instructions may cause AC plug damage.
Follow the steps below to strip the wires before assembling the AC plug as
shown in Figure 3-11 :
(1) Remove 55 mm (2.2 inch) of AC cable outer jacket.
(2) Trim the L-N(Grid), L-N(Load) wire to 52.5 mm (2.0 inch).
(3) Strip 10 mm (0.5 inch) of insulation from all wires ends.
(4) Crimp terminals for all wires.
- Any electric power connected to the battery pack during cabling is prohibited.
- Please make sure any breaker is turned off before connecting cables.
52.5 mm
[2.0 in.]
12 mm
[0.5 in.]
55 mm [2.2 in.] (PE)
Figure 3-11 : Striping the wires
DANGER: ELECTRICAL HARZARD!!
outer jacket