Majestic fireplaces DVBR36 Homeowner's Installation And Operating Manual
Majestic fireplaces DVBR36 Homeowner's Installation And Operating Manual

Majestic fireplaces DVBR36 Homeowner's Installation And Operating Manual

Builder direct vent

Advertisement

INSTALLER/CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from your neighbor's phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas supplier
call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
Builder Direct Vent
Models: DVBR36
Homeowner's Installation and
FP596A
1/14/99
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
DVBR42
Operating Manual
C E RT I F I E D
20000584 2/08 Rev. 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVBR36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic fireplaces DVBR36

  • Page 1: Safety Information

    Builder Direct Vent Models: DVBR36 DVBR42 INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    How to Use the Vent Graph ......................14 Rear Wall Vent Applications & Installation ................14 Vertical Sidwall Applications & Installation ................16 Below Grade Installation ......................20 DVBR36 Vertical Installation Baffle Adjustment ................20 Vertical Through-the-Roof Applications & Installation ...............21 Venting Components .........................23 Operating Instructions Glass Information ........................24...
  • Page 3: Installation & Operating Instructions

    FOR SAFE INSTALLATION AND OPERATION PLEASE gas valve be left in the OFF position. NOTE THE FOLLOWING: This fireplace gives off high temperatures and should be DVBR36 / DVBR42 located out of high traffic areas and away from furniture Certified to and draperies.
  • Page 4: Commonwealth Of Massachusetts

    DVBR Series Direct Vent Gas Fireplace Requirements for the Commonwealth of Inspection Massachusetts The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber.
  • Page 5: Fireplace Dimensions

    P - Rough Opening Width Rough Opening Height ���" ���" Electrical Access Gas Line Access Fig. 2 Fireplace specifications and framing dimensions. Ref. DVBR36 DVBR42 Specs - top vent 40” (1016 mm) 46” (1168 mm) 2/14/02 djt 36” (614 mm) 36” (914 mm) 36”...
  • Page 6 O - Rough Opening Width Rough Opening Height ���" ���" Electrical Access Gas Line Access Fig. 3 Fireplace specifications and framing dimensions. Ref. DVBR36 DVBR42 40” (1016 mm) 46” (1168 mm) Specs - rear vent 2/14/02 djt 36” (614 mm) 36” (914 mm) 36”...
  • Page 7: Locating Your Fireplace

    DVBR Series Direct Vent Gas Fireplace Locating Your Fireplace Fireplace Top of Combustion Chamber CFM146a LU584-1 Bottom of Door Trim Mantel Chart Fig. 1 Locating Gas Fireplace LU584-1 Locating unit A) Flat on wall B) Cross corner C) **Island Mantel Mantel from Top CFM146 2/4/99 djt...
  • Page 8: Hearth

    Check fireplace to make sure it is levelled and properly positioned. High Elevations NOTE: If the optional Metro Face Kit (DVBR36 only) Input ratings are shown in BTU per hour and are is to be installed, the fireplace may be placed on a certified without deration for elevations up to...
  • Page 9: Remote Switch Installation

    DVBR Series Direct Vent Gas Fireplace Always check for gas leaks with a mild EB-1 Electrical Box soap and water solution applied with a brush no larger than 1” (25 mm). Never The fireplace, when installed, must be elec- apply soap and water solution with a spray trically connected and grounded in accor- bottle.
  • Page 10: Optional Top Vent Application

    Optional Top Vent Application replace gasket. (Fig. 12) The DVBR36/42 fireplace is shipped as a rear vent unit. 7. Install flue pipe to top of unit with four (4) screws. Be If the layout requires a top vent, convert the unit follow- sure to replace gasket.
  • Page 11: General Venting

    DVBR Series Direct Vent Gas Fireplace DVBR42 Remove Insulation 1. Remove the seven (7) screws securing the heat shield cover plate to the fireplace. (Fig. a) Discard the heat shield cover plate. Remove Screws (7) Heat Shield Cover Plate FP1543 Fig.
  • Page 12: General Venting Information - Termination Location

    DVBR Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL ����� ������ Fixed Operable Closed CFM145a AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION AIR SUPPLY INLET Canadian Installations US Installations CFM145a DV Termin Location A = Clearance above grade, veranda, porch, 12”...
  • Page 13: General Information Assembling Vent Pipes

    DVBR Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall...
  • Page 14: How To Use The Vent Graph

    DVBR Series Direct Vent Gas Fireplace Twist Lock Pipes When using CFM Corporation twist-lock pipe, it is not necessary to use silicone to seal the twist-lock joints. The only areas that need silicone are the collars on the fireplace, the telescoping pipe (if used) and the hori- zontal termination connection (when necessary).
  • Page 15 DVBR Series Direct Vent Gas Fireplace Vent Opening - Combustible Wall 9³⁄₈" (240 mm) 20” (506 mm) Max. Framing 10³⁄₈" Detail (265 mm) Top View Flat Installation Fireplace Hearth FP1188 Vent Opening - Noncombustible Wall Fig. 19 Rear vent application, no elbows. 7¹⁄₂"...
  • Page 16: Vertical Sidwall Applications & Installation

    DVBR Series Direct Vent Gas Fireplace Finished Wall 12" (305mm) These ends These ends should 1/2" (13mm) screwed to appli- be even ance Vent Termination FP1472 Fig. 25 There must be a 1” rise in 24” length. Vertical Sidewall Applications Since it is very important that the venting system FP1005 maintain its balance between the combustion air...
  • Page 17 DVBR Series Direct Vent Gas Fireplace 7’ 3 x 90° 3 x 90° (178cm) Elbows Elbows 10’ (254cm) A + B = 17’ Max. FP1176 8’ (244cm) Fig. 26 Maximum three (3) 90° elbows per installation. 36" (914mm) Max. 36" V584-201 (914mm) Max.
  • Page 18 DVBR Series Direct Vent Gas Fireplace Vertical Sidewall Installation Max. Length 12” (294 mm) Twist Lock Pipe Step 1 #8 Screws (2) Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location.
  • Page 19 DVBR Series Direct Vent Gas Fireplace spring 5” (127 mm) from the previously installed spring. Sealing vent pipe and firestop gaps with high tem- Place the next spring 6” (152 mm) from the last spring. perature sealant will restrict cold air being drawn in Finally place the last spring 12”...
  • Page 20: Below Grade Installation

    DVBR Series Direct Vent Gas Fireplace Do not back fill around snorkel. Below Grade Installation A clearance of at least 4” must be main- When it is not possible to meet the required vent terminal tained between the snorkel and the soil. clearances of 12”...
  • Page 21 DVBR Series Direct Vent Gas Fireplace 5. Place firestop(s) #7DVFS into position and secure. (Fig. 43) Max. Height 40’ (12.2m) 6. Install roof support (Fig. 44) and roof flashing Min. Height 8’ (2.4m) making sure upper flange of flashing is below the shingles.
  • Page 22 DVBR Series Direct Vent Gas Fireplace Min. 2' (610 mm) 3 #5 Sheet 3 #5 Sheet Metal Screws Metal Screws per Joint per Joint Sealant Sealant Storm Storm Collar Collar TWL101a Fig. 46 Roof flashing. TWL101a Twist Lock Pipe 2/8/99 djt FP1185 Fig.
  • Page 23: Venting Components

    DVBR Series Direct Vent Gas Fireplace Venting Components 7TDVRVT - Through the wall Rear Vent Termination Starter Kit - 584A Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) venting components rear vent term Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) 4/6/99 djt Model 7TTVTK/TV Hot Touch Termination Kit Model 7TDVTVTK/TV Cool Touch Termination Kit...
  • Page 24: Operating Instructions

    DVBR Series Direct Vent Gas Fireplace Operating Instructions Glass Information Only glass approved by CFM Corporation Glass Frame may be used for replacement. Fireplace Front • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. Clamps •...
  • Page 25: Installation Of Logs

    Panels Installation of Logs 3/15/99 djt Log Chart 1 . Remove front glass. (See “Glass Removal” Section, Fig. 48) Logs DVBR36 DVBR42 2. Remove logs from packaging. Left Log 20008817 20008508 As with all plastics — these are not toys...
  • Page 26: Ember Material Placement

    DVBR Series Direct Vent Gas Fireplace 5. Place the front edge of the Left Cover Log on Figure 52 the front top edge of the burner between the last two left tines of the grate. Allow the bottom edge of the log to sit on the hearth. Place the Right Cover Log between the right two tines and rest the log up against the front face of the burner.
  • Page 27: Flame Characteristics

    Remove glass frame (See Glass Frame Removal Section). Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary. Fig. 56 Correct pilot flame appearance. Figure 57 DVBR36 LG389 Figure 58 DVBR42 ����� ������ ��� ������...
  • Page 28: Lighting & Operating Instructions

    DVBR Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. neighbor’s phone. Follow the gas supplier’s A.
  • Page 29: Troubleshooting

    DVBR Series Direct Vent Gas Fireplace Troubleshooting – Honeywell VS8421 Remove window frame assembly before service work START CHECK • Supply Line Hooked Up Gas Supply On • Shutoff Valve Open • Lockout Has Engaged. Wait 60 Seconds And Try Again. •...
  • Page 30: Troubleshooting Gas Control System

    DVBR Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 31: Fuel Conversion Instructions

    DVBR Series Direct Vent Gas Fireplace Fuel Conversion Instructions To convert the DVBR unit from one gas type to another follow these instructions: Cut here for 822 1. Remove control cover to gain access to valve. Valve Remove glass door. (See “Glass Frame Removal”, Page 23, Fig.
  • Page 32 DVBR Series Direct Vent Gas Fireplace Shutter Burner Pan Retaining Pilot Hood Screw Index Marks CO105 Pilot Bracket Air Shutter Front View Fig. 67 Removing pilot hood. CO103 Fig. 63 Remove air shutter from burner pan. CO103 Pilot Orifice Gas Conversion Air shutter CO105 Burner Pan...
  • Page 33: Maintenance

    DVBR Series Direct Vent Gas Fireplace Maintenance Burner and Burner Compartment To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting It is important to keep the burner and the burner or floating. compartment clean.
  • Page 34: Replacement Parts

    DVBR Series Direct Vent Gas Fireplace 1. DVBR42 1. DVBR36 15 a/b 25a/b 13 a/b 17a,b 18a/b 23a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
  • Page 35 DVBR Series Direct Vent Gas Fireplace DVBR36/42 (continued) Ref. Description DVBR36 DVBR42 Lava Rock Package 20000198 20000198 Mineral Wool Bagged 5110184 5110184 Ceramic Tile (Single) 57803 57803 Burner Housing with Tile 20008831 20008836 Manifold Tubing with Fittings 20000611 20000538 Ceramic Hearth panel (Left)
  • Page 36: Optional Accessories

    DVBR Series Direct Vent Gas Fireplace Optional Accessories Optional Fk-12 Fan Hook-up Remote Controls Optional remote control units are available to control 1. Remove control cover from unit. different functions of the appliance. 2. Remove glass door by rotating latches at bottom Model Functions Controlled corners of door.
  • Page 37: Decorative Glass Panels

    Side View Decorative Face Kit H102 The Metro Face Kit is designed for use on the DVBR36 Fig. 75 Rear ceramic panel placement. H102 only. rear ceramic support...
  • Page 38 DVBR Series Direct Vent Gas Fireplace 20000584...
  • Page 39: Warranty

    LIMITED LIFETIME WARRANTY DVBR Series Direct Vent Gas Fireplace PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY •...
  • Page 40 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com...

This manual is also suitable for:

Dvbr42

Table of Contents

Save PDF