General Venting - Vermont Castings Chateau DVT38 Installation Instructions And Homeowner's Manual

Direct vent decorative gas appliance
Table of Contents

Advertisement

MV
MV/VP PV
1
2
BLACK
WHITE
WHITE
To Receptacle
Supplied
in Valve Box
120 VAC RTN
WHITE
BLACK
GREEN
120 VAC HOT
40VA TRANSFORMER
FP1367
Fig. 11 Honeywell ignition module.
20006081
PILOT
HONEYWELL IGNITION MODULE
24V
GRD
24V
SENSE SPARK
3
5
6
8
9
HI
NOVA SIT 822 VALVE
BLACK
24 VAC HOT
BLACK
BLACK
WHITE
WHITE
WALL SWITCH
24 VAC RET
BLACK
WHITE
FP1367
Honeywell ignition
rocker switch
wiring
5/03

General Venting

Your fireplace is approved to be vented either through
the side wall, or vertical through the roof.
Only Vermont Castings, Majestic Products
venting components specifically approved and
labelled for this fireplace may be used.
Venting terminals shall not be recessed into a wall or
siding.
Horizontal venting must be installed on a level plane
without an inclining or declining slope.
There must not be any obstruction such as bushes, gar-
den sheds, fences, decks or utility buildings within 24"
(610mm) from the front of the termination hood.
Do not locate termination hood where excessive snow
or ice build up may occur. Be sure to check vent termi-
nation area after snow falls, and clear to prevent ac-
cidental blockage of venting system. When using snow
blowers, make sure snow is not directed towards vent
termination area.
Location of Vent Termination
It is imperative the vent termination be located observ-
ing the minimum clearances as shown on following
page.
Chateau™
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chateau dvt44

Table of Contents