Fig. 17 Support straps for horizontal runs.
A minimum of 2ʼ (610mm) vertical section off the top
of the unit is required, an elbow and a 1ʼ (305mm)
maximum horizontal run to get through a wall. (Fig.
18)
The maximum number of 45° elbows permitted per
side wall installation is two (2). These elbows can be
installed in either the vertical or horizontal run. (Fig.
19)
2'
(610mm)
2'
(610mm)
Fig. 18 Minimum vertical run / maximum horizontal run.
FP1237a
DVT44
horizontal plane
4/03
Fig. 19 Maximum vent run with elbows.
14
20ʼ (6 m)
Pipe
Straps
Every 3ʼ
(914 mm)
Clearance Sleeve
FP1012
Top vent max run
1/25/00 djt
FP1012a
Wall Open-
C L
ing
X
(DVT44) X = 7ʼ3¹⁄₄" (2216mm)
(DVT38) X = 6ʼ9⁷⁄₈" (2080mm)
FP1237a
FP1238
For each 45° elbow installed in the horizontal run,
the length of the horizontal run MUST be reduced
by 18" (45cm). This does not apply if the 45° elbows
are installed on the vertical part of the vent system.
For each 90° elbow installed in the horizontal run,
the length of the horizontal run MUST be reduced by
36" (91cm).
The maximum number of elbow degrees in a system
is 270°. (Fig. 20)
Example: In Figure 23
Elbow 1
=
Elbow 2
=
Elbow 3
=
Elbow 4
=
Total angular variation =
1
Fig. 20 Maximum number of elbow degrees.

Sidewall Installation

STEP 1
Locate vent opening on the wall. It may be necessary
to first position the fireplace and measure to obtain hole
location. Depending on whether the wall is combustible
or noncombustible, cut opening to size. (Fig. 21)
For combustible walls first frame in opening.
Combustible Walls: Cut a 16¹⁄₄"H x 16¹⁄₄" W (413mm
x 413mm) hole through the exterior wall and frame as
shown.
Noncombustible Walls: Hole opening must be 11¹⁄₄"
(286mm) in diameter.
STEP 2
Measure wall thickness and cut zero clearance sleeve
parts to proper length (MAXIMUM 12"/305 mm). As-
semble sleeve using #8 sheet metal screws (supplied).
(Fig. 22) Install firestop assembly. (Fig. 31)
Zero clearance sleeve is only required for
combustible walls.
STEP 3
Slide the zero clearance sleeve through the wall and
install the firestop on the inside surface of the wall.
Secure with four (4) #8 sheet metal screws.
4
90°
45°
45°
90°
270°
3
2
FP1239a
FP1239a
Sidewall maximum
bends
DVT44
4/03
20006081