General Venting - Vermont Castings Chateau DVT38 Installation Instructions And Homeowner's Manual

Direct vent decorative gas appliance
Table of Contents

Advertisement

MV
MV/VP PV
1
2
RED
ORANGE
To Receptacle
Supplied in
Valve Box
120 VAC RTN
WHITE
BLACK
GREEN
120 VAC HOT
40VA TRANSFORMER
FP1225
Fig. 11 Honeywell ignition module.
20009145
PILOT
HONEYWELL IGNITION MODULE
24V
GRD
24V
SENSE SPARK
3
5
6
8
9
GREEN
BLACK
ORANGE
HI
NOVA SIT 822 VALVE
BLUE
24 VAC HOT
BLACK
BLACK
WHITE
YELLOW
24 VAC RET
WALL SWITCH
BLACK
WHITE

General Venting

Your fireplace is approved to be vented either through
the side wall, or vertical through the roof.
Only CFM Corporation venting components spe-
cifically approved and labelled for this fireplace
may be used.
Venting terminals shall not be recessed into a wall or
siding.
Horizontal venting must be installed on a level plane
without an inclining or declining slope.
There must not be any obstruction such as bushes, gar-
den sheds, fences, decks or utility buildings within 24"
(610 mm) from the front of the termination hood.
Do not locate termination hood where excessive snow
or ice build up may occur. Be sure to check vent termi-
nation area after snow falls, and clear to prevent ac-
cidental blockage of venting system. When using snow
blowers, make sure snow is not directed towards vent
termination area.
Location of Vent Termination
It is imperative the vent termination be located observ-
ing the minimum clearances as shown on following
page.