Termination Clearances - Vermont Castings Chateau DVT38 Installation Instructions And Homeowner's Manual

Direct vent decorative gas appliance
Table of Contents

Advertisement

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
A
V
Balcony -
with no side wall
G =
Combustible &
Noncombustible
12"(305mm)
Fig. 13 Termination clearances.
Quick Reference for Fresh Air Restrictor Plate / Flue Baffle
Application
SK8DVSK
Vertical Less than 12'
Vertical 12' to 20'
Vertical 20' to 30'
Vertical 30' to 40'
20006081
Outside Corner
A =
Combustible
6"(152mm)
V
Noncombustible
2"(50mm)
Balcony -
with perpendicular side wall
G
V
Combustible &
Noncombustible
H = 24"(610mm)
J = 20"(508mm)
Item
Flue Restrictor Plate
Fresh Air Restrictor Plate
Flue Restrictor Plate
Fresh Air Restrictor Plate
Flue Restrictor Plate
Fresh Air Restrictor Plate
Flue Restrictor Plate
Fresh Air Restrictor Plate
Flue Restrictor Plate
Fresh Air Restrictor Plate
B =
Combustible
6"(152mm)
Noncombustible
2"(50mm)
B
H
V
J
DVT38N
DVT38P
3"
None
None
None
None
None
None
None
4¹⁄₂"
4¹⁄₂"
#3
#3
4¹⁄₂"
4¹⁄₂"
#2
#2
4¹⁄₂"
4¹⁄₂"
#1
#1
Chateau™
Recessed Location
D
C
C
E
V
C = Maximum depth of 48"
(1219mm) for recessed
location.
D = Minimum width for back wall
of a recessed location.
Combustible 38"(965mm)
Noncombustible 24"(610mm)
E = Clearance from corner in
recessed location.
Combustible 6"(152mm)
Noncombustible 2"(50mm)
DVT44N
DVT44P
None
4¹⁄₂"
None
#1
None
None
None
None
4¹⁄₂"
4¹⁄₂"
#3
#3
4¹⁄₂"
4¹⁄₂"
#2
#2
4¹⁄₂"
4¹⁄₂"
#1
#1
584-15