12���"
(311mm)
Fig. 8 Valve box framing.
7. The U-channel located on the top of the unit as well
as the nailing flanges on the sides that were men-
tioned in Step 1, are designed to accommodate non-
combustible board (recommended Dura-Rock). They
are positioned 1" (25mm) back from the face of the
FP1362
unit. NOTE: The U-channel depth can be adjusted
component box framing
by loosening the hex nut inside the channel.
5/03 djt
If marble, tile or any other noncombustible decora-
tive face finish material is desired, a 3" (76mm) wide
noncombustible board (recommended Dura-Rock)
is to be nailed to the nailing flanges on both sides
of the unit. Also, 12" (305mm) of noncombustible
board is to be nailed to the front face of the U-chan-
nel and the top framing member above the standoff.
Combustible material can then be brought to the
outside edges of the noncombustible board installed
earlier. Any noncombustible decorative face finish
could be brought to the sides and top of the unit and
can cover the framing and sheet rock. If a decora-
tive facing is not desired, then the noncombustible
boards must be double thickness and brought flush
with the face of the unit.

Final Finishing

Noncombustible materials such as brick or tile may be
brought to the edges of the face of the appliance.
DVT38 / DVT44
Certified To
ANSI Z21.50b-2002/CSA 2.22b-2002
Vented Gas Fireplace
DVT38 Units: GF1HC0, GF1IC0, GF1AC0, GF1BC0
DVT44 Units: E21H00, E21I00, E21A00, E21B00

Gas Inlet and Manifold Pressures

Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
20006081
9���"
(235mm)
FP1362
Natural
LP (Propane)
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5" w.c.
10.0" w.c.
Gas Specifications
MODEL
FUEL
DVT38RN
Natural Gas
DVT38RP
Propane
DVT38EN
Natural Gas
DVT38EP
Propane
DVT44RN
Natural Gas
DVT44RP
Propane
DVT44EN
Natural Gas
DVT44EP
Propane

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).
WARNING: Improper installation, adjust-
ment, alteration, service or maintenance
can cause injury or property damage. Refer
to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or the gas supplier.

Gas Line Installation

When purging gas line the front glass must
be removed.
A gas shut off valve must be installed on
the gas pipe line going into the appliance
within easy access.
The gas pipeline can be brought in through the bottom
right side of the valve box assembly.
The gas line connection can be made with properly
tinned 1/2" copper tubing or 1/2" gas tight. Some
municipalities have additional local codes, it is always
best to consult your local authority and the CSA-B149.1
installation codes.
For USA installations consult the current National Fuel
Gas Code, ANSI Z223.1/NFPA 54.
Chateau™
MAX.
MIN.
GAS
INPUT
INPUT
CONTROL
B.T.U.H
B.T.U.H.
Millivolt
46,000
34,000
Millivolt
46,000
36,000
24V Hi/Lo
46,000
34,000
24V Hi/Lo
46,000
36,000
Millivolt
60,000
37,000
Millivolt
60,000
45,000
24V Hi/Lo
60,000
37,000
24V Hi/Lo
60,000
45,000
7