Lift-up curved glass, refrigerated service gelato and ice cream case (26 pages)
Summary of Contents for Hussmann VR3-M Series
Page 1
/SPECIALTY 22018 VR3-M/HV-M MEAT SERVICE MERCHANDISER U S E R M A N U A L - VR3-M/F-4-R - VR3HV-M/F-4-R - VR3-M/F-6-R - VR3HV-M/F-6-R - VR3-M/F-8-R - VR3HV-M/F-8-R - VR3-M/F-12-R - VR3HV-M/F-10-R Remote - VR3HV-M/F-12-R...
Exterior Surfaces Line Sizing Interior Surfaces Oil Traps Troubleshooting Piping Schematic Refrigeration Spec Sheets DOE 2017 Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Compliant...
Shortages: Check your shipment for any possible shortages of material (See Parts List page 11). If a shortage should exist and is found to be the responsibility of Hussmann Chino, notify Hussmann Chino. If such a shortage involves the carrier, notify the carrier immediately, and request an inspection.
Case is to arrive at store as was shipped form factory. See reference above for proper shipment referencing. (Not actual case) Receiving Case Upon receiving your new Hussmann Case all equipment should be thoroughly examined for shipping damage before and during unloading. This equipment has been carefully inspected at our factory.
Installation (cont’d) Placement Move the fixture as close as possible to its per- Important: See lifting instructions to properly lift manent location and then remove all packag- case when being placed on dollies or permanent ing and prepare to remove off Skid. Remove all location. (See page 7 for Lifting Instructions.) separately packed accessories such as kits, and panels.
Installation (cont’d) VR3HV-M/F Lifting and Transport 5. The VR3HV-M/F merchandiser can be raised Instructions at one end underneath the deck with a forklift to allow the placement of rollers or dollies. 1. The VR3HV-M/F can be lifted by a forklift at 6.
Installation (cont’d) Leveler Adjustment Position the case at the highest point. Set a long magnetized level (4ft [1220 mm] or more) on either underneath the deck or on top of the case. Ensure to level case from front to back and side Level to side.
Installation (cont’d) Setting and Joining 1. Using case blueprints, measure off and mark The sectional construction of these models en- on the floor the exact dimensions of where the able them to be joined in line to give the effect of cases will sit. Snap chalk line for front and back one continuous display.
Page 10
Installation (cont’d) 3. Set second case within one foot (1’) of the first 5. Apply liberal bead of case joint sealant (bu- case. Keep the supports along the length of the tyl) to first case. Sealant area is shown using a case and far end of case. Level case to the first striped line in illustration in page 16. Apply heavy using the instructions in step one. amount to cover entire shaded area. 4.
Page 11
Installation (cont’d) 7. To compress butyl at joint, use two Jurgenson wood clamps. Make sure case is level from front to back and side to side on inside bulkheads at joint. 8. Attach sections together via the bolts pictured in the illustration below. 9.
ARM ADJUSTMENT (NON HV-D) VR3 (non HV) Arm Adjustment STEP 3. Loosen lock bolt. STEP 4. With bolt loose, set arms to required level and support. Insert shims in locations STEP 1. Ensure case is level to the ground. indicated in the diagram. Check level at the bulkhead.
Installation (cont’d) VR3HV Glass Adjustment Glass must be parallel to ledge when viewed from front. Glass height should be centered on “V” glass seal as demonstrated below. Follow these steps accordingly to properly and safely adjust the position of the front glass. BEFORE ADJUSTING GLASS • SET, LEVEL, AND BOLT TOGETHER ALL CASES. • DOUBLE CHECK LEVELING FOR ALL CASES. • DO NOT MOVE LINEUP DURING ADJUST- MENT.
Installation (cont’d) Front Body Panel Install Fasten Rear Body Panel Install (1) Align clips of rear panel to Base Legs of case No tools will be needed to (2) Secure top and bottom clips of rear panel to install body panels. Base Les as shown below.
In the case pressure was not sealed at factory already. Seal both the inside maintained contact your Hussmann Service Tech and outside. We recommend using an expanding for further assistance.
Page 18
Refrigeration (cont’d) See demonstrations below for detailed overview of the VR3HV-M/F C/S-EP Piping schematic. Note: Refrigeration components have been fitted with a component tray for ease in use of cleaning and maintenance under the deck pans. SOLENOID HAND VALVE FILTER DRIER...
Electrical Field Wiring Merchandiser Electrical Data Field wiring must be sized for component am- Technical data sheets are shipped with this peres stamped on the serial plate (refer to pg 16 manual. The data sheets provide merchandiser for location). Actual ampere draw may be less electrical data.
Electrical Cont’d Remove Rear Raceway Electrical Conduit (Electrical Box) The Merchandisers Electrical access is located The Merchandisers Electrical conduit can be at the rear of the case. Fasteners must be re- found inside the compartment at the rear. Re- moved in order to gain access. See illustration moving the raceway will gain access to the elec- below.
User Information Start Up Load Limit See the merchandisers Data Sheet Set for refrig- Each Merchandiser has a Load Limit. Shelf life of erant settings and defrost requirements. Bring perishables will shorten if Load Limit is violated. merchandisers down to the operating tempera- AT NO TIME SHOULD THE MERCHANDISER tures listed on the Data Sheet.
SETUP TROUBLE SHOOTING sec- equipped with easy adjustment features for vary- tion. ing store conditions. Please refer published case specifications on Baseline Settings Hussmann website 75°F and 55%RH* ambient store conditions • Evaporator temperature: 28° F specific re- Refer to A419 Display Symbols, Control Func- frigerant equivalent (with coils under load) tion, Ranges, Units, Values, and Factory Settings •...
User Information (cont’d) Merchandising Requirements Use a consistent display strategy in each case . Rotate product every several hours. Bottom layer Hussmann recommends the use of flat bottomed should be rotated to the top and flipped. This aluminum or high density plastic trays as the ensures even cooling, dehydration and color ideal merchandising display method.
Products can be stacked too high on trays or dis- rations are NOT RECOMMENDED and working play ware, the Spiral serpentine coil underneathe outside of the Hussmann requirements will ad- the deck pans are the main source for cooling versely affect product and/or case performance.
Maintenance Case Cleaning Clean frequently to avoid build-up of hard, stub- Long life and satisfactory performance of any born stains. A stainless steel cleaning solution equipment are dependent upon the care it re- may be used periodically to minimize scratching ceives.
Page 38
Maintenance Cont’d Do Not Use: • Abrasive cleaners and scouring pads, as these will damage the finish. WARNING • A hose on lighted shelves or submerge light- ed shelves in water. • Solvent, oil or acidic based cleaners on any Product will be degrade and may spoil if interior surfaces.
Troubleshooting Problem Possible Cause Possible Solution Product too cold Spiral Deck Coil (SDC) is Probe the deck with the product in place. If the deck is less and/ or freezing too cold. than 29°F increase the SDC thermostatic SP incrementally. Allow approximately 60 minutes or stable temperatures for system to react then recheck temperatures.
Page 40
MERCHANDIZING RECOMMENDATIONS (page 29) section the conduction cooling for further information. from the SDC Incorrect replacement Use only Hussmann genuine replacement parts or equivalent. lighting is adding too much heat Case temperature is Ambient conditions may Check case position in store. Is the case located near an too warm.
Page 41
Troubleshooting Cont’d Problem Possible Cause Possible Solution Case temperature is The t-stat temp is set too Check settings. See Technical Specifications section. too cold. low. Ambient conditions may Check case position in store. Is the case located near an be affecting the case open door, window, electric fan or air conditioning vent that operation.
Page 42
To obtain warranty information or other support, contact your Hussmann representative. Please include the model and serial number of the product. Hussmann Warranty / Technical Assistance (800) 592-2060 Hussmann Corporation, Corporate Headquarters: Bridgeton, Missouri 63044 2014...