Husqvarna CT 36 Series Operator's Manual page 33

Table of Contents

Advertisement

Operation
Continued from the previous page.
Final
1. Connect the wires (s) from the handle to the wires (t) from the engine. Observe
assembly
the following when connecting the engine wires:
■ Honda engines have yellow wires to connect to the handle wires.
■ Wacker Neuson engines have orange wires to connect to the handle wires.
2. Connect the green ground wire from the handle to the green wire from the
engine. If the machine already has the green wire on the engine, discard the
one supplied with the handle. If the machine does not have the green ground
wire, remove the nut (u) from the engine stud, attach the ground wire, and
tighten the nut to 25 Nm (18 ft. lbs.).
Adjusting the
1. Position the adjustable handle by loosening the lever (v) and adjusting the
handle
handle up or down to suit the operator.
2. Tighten the lever to secure the handle in position.
Final check
1. Start the engine and check the idle RPM. The specification is 1450±100 RPM.
2. Quickly move the handle counterclockwise to test the engine control module
function. The engine should stop.
CAUTION
► If the engine does not stop automatically, shut down the machine manually.
Have an authorized dealer service the machine before using.
NOTICE: When storing the machine, do not fully pitch the trowel blades and fold
the handle. The pitch control cable and possibly the pitch assembly may be
damaged. Flatten the trowel blades before folding the handle.
Walk-Behind Trowels
t
s
u
34
v
wc_gr014684
wc_tx004127gb_FM10.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents