MOVIE
5-4-5 WB Adjustment (3)
CHART
Light box (5600°K)
SPEC.
Automatic adjustment
Procedure)
(1) Referring to the table shown below, carry out WB adjustment (3).
ST EP PROCEDURE
WB (3)
1
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
5-4-6 Virtual EEPROM and Flash Memory Writing
SPEC.
Automatic writing
Procedure)
(1) According to the table shown below, write adjustment data (5-4-1 to 5-4-5) into the virtual EEPROM and flash memory.
ST EP PROCEDURE
EEPROM & FLASH WRIT ING
1
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
2
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
MONIT OR
CS Function MD ADDR DT
2
08
ST
3005
00
WR
↑
↑
↑
↑
RD
↑
↑
↑
MONIT OR
CS Function MD ADDR DT
2
08
ST
3006
00
RD
↑
↑
↑
0
08
ST
0081
--
RD
↑
↑
↑
↑
20
MV750i E, MV730i E, MV700i E, MV700 E, MV690 E
SERVICE MODE · ADJUSTMENT
Microcomputer operation
ST
Adjustment is in progress.
05
Adjustment is completed.
Completion with ST :05 (ST :09 NG)
Microcomputer operation
ST
05
Completion of virtual EEPROM writing.
Completion with ST :05, ST :09 NG
Preparation for flash memory updating.
Execution of flash memory updating.