Progress Of Charging - Canon MV750i E Service Manual

Ipal
Table of Contents

Advertisement

3-2-2 Progress of Charging

When the conditions described in 3-2-1 are satisfied, the MODE MI-COM starts charging according to the specifications in Fig. 5.
The charging current in quick charge can be restricted by Compact Adapter (CA-570 / CA-570S).
* Charging is allowed to start provided that the UNREG voltage is 8.4 0.3V before
starting the charging. Otherwise, an error is indicated.
* Charging can be performed provided that the power is turned OFF.
* If the DC JACK is detected, the charging is turned OFF when the power is turned ON
(no power supplied from the battery).
LED flashes once
Quick charge 1.525A 0.075A
When battery voltage
becomes
quick charge starts.
* An error is indicated and charging is turned OFF if the battery voltage becomes 6.4V
or lower during charging other than trickles 1 and 2.
* An error is indicated and charging is turned OFF if the battery voltage becomes 5V
or lower during charging trickle 2.
* An error is indicated and charging is turned OFF if the charging voltage is 1.8A or higher.
* Charging is turned OFF if the charging current is 70mA or lower.
* An error is indicated if, at a start of quick charge, D terminal voltage is varied 0.15V toward
positive side or 0.3V toward negative side.
If the battery voltage
becomes
the trickle 2 starts.
350mA max.
Trickle 1
40mA max.
BATT V 5.2V
INIT-CHG1 OFF
INIT-CHG2 ON
INIT-CHG3 OFF
Torque 1 timer
110 min. max.
Error indicated and
charging OFF at timeout
5.2V BATT V 6.5V
INIT-CHG1 OFF
INIT-CHG2 ON
INIT-CHG3 ON
Torque 2 timer
100 min. max.
Error indicated and
charging OFF at timeout
0.75A
ADI detection voltage
6.5V,
= 1.118V
5.2V,
TOTAL TIMER
BATT V 6.5V
ADI detection voltage
1.118V
INIT-CHG1 ON
INIT-CHG2 ON
INIT-CHG3 OFF
Quick charge timer
Error indicated and
charging OFF at timeout
BP-508/511/512/514 : 100min.max
BP-522 : 150min. max
BP-535 : 200min. max
Total timer
LED lit and charging ended at
timeout
BP-508/511/512/514 : 5Hmax
BP-522 : 7.5Hmax
BP-535 : 10Hmax
MV750i E, MV730i E, MV700i E, MV700 E, MV690 E
Up to battery installed/removed
LED flashes twice
If the battery is not installed/removed
after completion of charge, charging
does not start unless the battery voltage
becomes 7V or lower.
100mA
ADI detection voltage
= 0.147V
BATT V 8.0V
0.147V ADI detection voltage
1.118V
INIT-CHG1 ON
INIT-CHG2 ON
INIT-CHG3 OFF
2-flash timer
LED lit and charging ended at
timeout
BP-508/511/512/514 : 138min.max
BP-522 : 207min. max
BP-535 : 276min. max
BATT V 8.0V
0.105V ADI detection voltage 0.147V
INIT-CHG1 ON
INIT-CHG2 ON
INIT-CHG3 OFF
Supplementary timer
LED lit and charging ended at
timeout
BP-508/511/512/514 : 1Hmax
BP-522 : 1Hmax
BP-535 : 1Hmax
Fig. 5
8
TECHNICAL DESCRIPTION
LED lights up steadily
and power turned ON
70mA
ADI detection
voltage
= 0.105V
Lapsed time
Charge
ended
BATT V 8.0V
ADI detection voltage
0.109V
INIT-CHG1 OFF
INIT-CHG2 OFF
INIT-CHG3 OFF