Reviewing Test Results - Fora Advanced pro GD40g Owner's Manual

Hide thumbs Also See for Advanced pro GD40g:
Table of Contents

Advertisement

Available languages

Available languages

Measuring Blood Glucose Test
1. Insert the test strip into its slot.
Wait for the device to display the test strip and blood drop symbol.
2. Select the appropriate measuring mode by pressing MAIN.
• General Tests (
) - any time of day without regard to time
since last meal.
• AC (
) - no food intake for at least 8 hours.
• PC (
) - 2 hours after a meal.
• QC (
) - testing with the control solution.
3. Obtain a blood sample. (n)
Use the pre-set lancing device to puncture your desired site.
After penetration, discard the first drop of blood with a clean
tissue or cotton. Gently squeeze the punctured area to obtain
another drop of blood. Be careful NOT to smear the blood
sample. The volume of blood sample must be at least 1.1
microliter (μL) of volume.
4. Apply the blood sample. (o)
Hold the blood drop to touch the absorbent hole of the test
strip. Blood will be drawn in and after the confirmation window
is completely filled, the device begins counting down. Do not
remove your finger until you hear a beep sound.
5. Read your result. (p)
The results of your blood glucose test with hematocrit (HCT)
and hemoglobin (Hb) levels will appear after the meter counts
down to 0. The results will be stored in meter's memory
automatically.
Disposing Used Test Strip and Lancet
To remove the used test strip, simply press the Test Strip Ejector
to eject the used test strip. The device will automatically turn off
after the test strip is ejected.
To remove the used lancet, remove the lancet from the lancing
device after you have finished testing.
Discard your used strip and lancet properly in a puncture resistant
container.
Important!
The used lancet and test strip may be biohazards. Please consult
your health care provider for proper disposal complying with your
local regulations.

Reviewing Test Results

Your device stores the 200 most recent test results along with
respective dates and times in its memory.
To review all test results, do the following:
1. Press and release MAIN. The "
2. Press MAIN to review the test results stored in the device. Press
MAIN repeatedly to review other test results stored in the
device. (q) After the last test result, press MAIN again and the
device will be turned off.
To review the day-average test results, do the following:
1. Press and hold MAIN for 3 seconds until the "
appears. Release MAIN and then your 7-day average result
measured in general mode will appear on the display.
EN-7
ADVANCED pro GD40g Owner's Manual
" icon appears on the screen.
" icon