Fora Diamond CUFF BP Owner's Manual
Hide thumbs Also See for Diamond CUFF BP:

Advertisement

Quick Links

CUFF BP
Blood Pressure Monitoring System
Blutdrucküberwachungssystem
Système de surveillance de la tension artérielle
Sistema per il monitoraggio della
pressione sanguigna
Sistema de supervisión de presión en sangre
Σύστημα παρακολουθήσης αρτηριακής πίεσης
Bloeddrukbewakingssysteem
Tansiyon Ölçüm Sistemi
Прибор для измерения кровяного давления
Tonometr
Sistema de monitorização de pressão arterial
Sistem de monitorizare a tensiunii arteriale
Owner's Manual
Bedienungsanleitung
Manuel de l'utilisateur
Manuale dell'utente
Manual del propietario
Εγχειρίδιο χρήσης
Handleiding
Kullanıcı El Kitabı
Руководство пользователя
Příručka vlastníka
Manual do utilizador
Manual de utilizare

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Diamond CUFF BP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fora Diamond CUFF BP

  • Page 1 CUFF BP Owner’s Manual Blood Pressure Monitoring System Bedienungsanleitung Blutdrucküberwachungssystem Système de surveillance de la tension artérielle Manuel de l’utilisateur Sistema per il monitoraggio della Manuale dell'utente pressione sanguigna Manual del propietario Sistema de supervisión de presión en sangre Σύστημα παρακολουθήσης αρτηριακής πίεσης Εγχειρίδιο...
  • Page 2: Safety Information

    Read the following Safety Information throughly before using the Intended Use device. The Diamond CUFF BP Blood Pressure Monitoring System is • Use this device ONLY for the intended use described in this manual. intended to be used to measure the systolic and diastolic blood •...
  • Page 3: Product Overview

    Product Overview 7. Units for Blood Pressure 3. IRB (Irregular Rapid Beat) Symbol 8. Diastolic Pressure Symbol 4. Low Battery Symbol 9. Pulse Rate 10. Pulse Rate Symbol Getting Started Installing the Batteries Before using the device for the first time, please install four 1.5V AAA size alkaline batteries.
  • Page 4: Installing The App

    Pairing with Your Mobile Device 3. Tap DIAMOND CUFF BP to start pairing. The Bluetooth LED To pair your Diamond CUFF BP with your mobile device, do the indicator will blink during the pairing process. following: 4.
  • Page 5: Testing Your Blood Pressure

    Note: Note: • If the device is left idle for 3 minutes, it will turn off automatically. • Before using the cuff, be sure the cuff size fits with your upper • The Bluetooth pairing process is only required when user needs to arm circumference.
  • Page 6: Single Measurement

    Important! Always apply the pressure cuff before turning on the device. A. Single Measurement Perform an individual blood pressure measurement. 1. Press the Power button. All the LCD symbols will appear. Then the cuff will begin to inflate automatically. Important! Note: •...
  • Page 7 B. Average Measurement (via APP) Automatically performs three (3) consecutive blood pressure measurements and displays the average result in the end. This function is only available when your Diamond CUFF BP is connected to your mobile device. 1. Press the Bluetooth button. The “...
  • Page 8: Reviewing Test Results

    To DISPOSE OF USED BATTERIES ACCORDING TO THE recall the memory, you have to connect your Diamond CUFF BP INSTRUCTIONS. to your mobile device. Once connected, the measured data is Note: automatically imported to iFORA BP app.
  • Page 9: Troubleshooting

    Caring for Your Device Battery is too low. Replace the batteries. • To clean the device exterior, wipe it with a cloth moistened with tap water or a mild cleaning agent, then dry the device with a soft dry cloth. Do NOT flush with water. Problem with the Please contact local customer •...
  • Page 10: Reference Values

    Reference Values Symbol Information Blood Pressure Symbol Referent Human blood pressure naturally increases after reaching middle Read instructions before use age. This symptom is a result of continuous ageing of the blood vessels. Further causes include diabetes, lack of exercise and Manufacturer cholesterol (LDL) adhering to the blood vessels.
  • Page 11: Specifications

    Specifications WARRANTY TERMS AND System performance CONDITIONS Power Source Four 1.5V AAA alkaline batteries With respect to disposable products, ForaCare Suisse warrants Dimensions (w/o cuff ) 145 (L) x 64.5 mm (W) x 29.6 mm (H) to the original purchaser that, at time of delivery, each standard Weight (w/o cuff ) 240g (without batteries) product manufactured by ForaCare Suisse shall be free of defects...
  • Page 12 Sistema de monitorização de pressão arterial Sistem de monitorizare a tensiunii arteriale For self-testing/Zur Selbstmessung/ Pour l'auto-test/Per test autodiagnostici/ Para autotest/ /Kendi kendine ölçüm için/ ForaCare Suisse AG Para auto-diagnóstico/Pentru autotestare Neugasse 55, 9000 St. Gallen, Switzerland FORA P80 www.foracare.ch ver 2.0 2019/01 311-3140100-013...