INSTRUCTIONS FOR GEL AND LEAD-ACID BATTERIES
Only carry out work on batteries
according to battery manufacturer's
instructions.
Wear safety glasses and clothing when
working on batteries.
Observe the accident prevention rules
and regulations.
Smoking is strictly prohibited.
Keep battery away from open flames,
glowing objects and sparks, otherwise
there is a danger of explosion and fire.
Immediately rinse any acid splashed
into eyes or onto skin out or off with
plenty of clean water. Then immediately
consult a physician.
Wash out clothing contaminated with
acid with water.
Avoid short circuits! Explosion and fire
hazard!
1. Preparing for operation
The batteries are to be checked to
ensure proper mechanical condition.
Battery connectors and charging plugs
are to be connected to the proper
terminals, as otherwise the batteries and
the charging set may be destroyed.
The
connection
connectors of the machine and/or the
charger may take place only with the
key switch and/or the charger switch off.
2. Discharging
The vent openings in the machine must
not be closed or covered.
Opening
or
connections (e.g. plugs, connectors,
etc.) may take place only in the
currentless state with the main switches
off.
In order to reach an optimum service
life, discharges are permissible only up
to the point at which a certain residual
capacity is reached.
3. Charging
WARNING!
Only use chargers approved by Cleanfix for charging.
Safety, Operation and Maintenance Manual for Falcon (RA 530 B); Version 1.0
with
the
battery
closing
of
electrical
WARNING! Metal parts in the battery
cells are always live. Therefore, do not
put/store objects or tools on the battery.
Electrolyte is extremely caustic. Contact
with the electrolyte is not possible during
normal operation.
In the event of destruction of the casing
of maintenance-free gel batteries, the
bound electrolyte released is just as
caustic as the liquid electrolyte.
Acid and/or batteries filled with acid
must not be handled by children.
Use only approved lifting and transport
equipment.
Lifting hooks must not cause damage to
cells,
connectors
cords/cables.
Maintenance-free, sealed gel batteries:
The batteries are to be recharged
before being put into operation.
Lead-acid batteries:
For reasons of durability unfilled, pre-
charged lead-acid batteries should be
charged immediately before insertion.
Observe the battery manufacturer's
instructions when doing so.
In order to avoid total discharge, the
controls of the machine contain an
automatic
switch-off
switches off the main feed line in time
when cut-off voltage is reached and
signals this by means of a red warning
lamp. Discharged batteries are to be
charged immediately and must not be
left in the discharged state. This also
applies after partial discharging.
or
connection
device
which
13