Technical Data; Dimensions - BARTEC BENKE A Series Instruction Manual

Gauging unit
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

3.2

Technical Data

Electrical data
Power supply
Backup fuse
Compressed air
MID measuring accuracy
Pump output
Ambient conditions
Operating temperature
Storage temperature
Mechanical data

Dimensions

Weight
Sound pressure level
Hose connection
Network connection
3.3
Dimensions
Instruction Manual PETRO 3003 VOLUTANK Gauging unit BA 140918
AC 400 V 50 Hz max. 4 kVA
Line cut-out 3x16 A (characteristic C)
A universal residual-current circuit-breaker is
recommended.
The leakage current can exceed 30 mA when the unit
is switched on!
6 bar to max. 8 bar
+-0.3% in 25l/min to 500l/min range
(but not less than +- 0.2l)
Max. 300 l/min
+15 °C ... +35 °C
+5 °C ... +50 °C
See dimensional drawing
Approx. 190 kg
Approx. 90 dB(A)
ELAFLEX MK 50 conforming to DIN EN 14420-6
(DIN 28450)
RJ45