Special Function "Pump Over - BARTEC BENKE A Series Instruction Manual

Gauging unit
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Operation of the gauging unit
37
5.3.4

Special function "pump over"

The special function automatically controls the required valves and the
pump:
Vehicle chambers and external tanks can be connected at the respective
connection (IN, OUT1, OUT2). When vehicle chambers are connected, a
check takes place during the filling process to determine whether the float
gauge is moving and otherwise the pump is stopped.
The filling mode "Pump" requires a setting for both the pump speed and
pump direction. This is not necessary with the filling mode "Bypass".
The pump does not cut out automatically - the operator is required to
switch it off manually!
When the transfer pumping process has started, the relevant information
is displayed and the stop button is enabled:
Instruction Manual PETRO 3003 VOLUTANK Gauging unit BA 140918

Advertisement

Table of Contents
loading

This manual is also suitable for:

Volutank petro 3003

Table of Contents