INITIAL PARAMETER SET UP

5. Initial Parameter set up (Users' set up)

It will be operated with the default value of the essential user settings when it is connected to a 12V
battery for the first time. The screen displays the following information in sequence and the user can
It will be operated with the default value of the essential user settings when it
change the value of parameter on each screen.
is connected to a 12V batttery for the first time.The screen displays the following
When you are willing to alter the parameter value in the program, press Start/Enter key to make it
information in sequence and the user can change the value of parameter on each
blink then change the value with INC or DEC key. The value will be stored by pressing Start/Enter
screen.
key once.
When you are willing to alter the parameter value in the program, press Start/
Enter key to make it blink then change the value with INC or DEC key. The value will
be stored by pressing Start/Enter key once.
The screen displays the nominal voltage of Lithium battery.
The screen displays the nominal voltage of Lithium
battery. There are three kinds of Lithium battery;
There are three kinds of Lithium battery; LiFe(3.3V),Lilo(3.6V)
LiFe(3.3V),Lilo(3.6V) or LiPo(3.7V). This is very
or LiPo(3.7V). This is very important so you have to check the
important so you have to check the battery carefully
battery carefully and set it up correctly. If it is different from
and set it up correctly. If it is different from correct
correct value the battery can explode during charge process.
value the battery can explode during charge process.
It recognise the cell count of Lithium battery automatically at
It recognise the cell count of Lithium battery
automatically at the beginning of charge or discharge
the beginning of charge or discharge process to avoid from
process to avoid from erroneous setting by user. But
erroneous setting by user. But deeply discharged battery can
deeply discharged battery can be perceived incorrectly.
be perceived incorrectly. To prevent the error, you can set the
To prevent the error, you can set the time term to verify
time term to verify the cell count by the processor. Normally,
the cell count by the processor. Normally, 10 minutes
are enough to perceive the cell count correctly. For
10 minutes are enough to perceive the cell count correctly.
the battery of larger capacity, you may extend the
For the battery of larger capacity, you may extend the time
time term. But if you set the time term too long for the
term. But if you set the time term too long for the battery of
battery of smaller capacity, the charge or discharge
smaller capacity, the charge or discharge process can be
process can be finished within the time term with the
erroneous cell count. This may cause the fatal result.
finished within the time term with the erroneous cell count.
If the processor recognises the cell count incorrectly at
This may cause the fatal result. If the processor recognises
the beginning of charge or discharge process, you may
the cell count incorrectly at the beginning of charge or dis-
extend the time. Otherwise, you had better use with
charge process, you may extend the time. Otherwise, you
the default value.
had better use with the default value.