  • Page 1 LiPo LiHV LiFe LiIon SCAN QR-CODE NiMH • Mode d’emploi en Francais NiCd • Nederlandstalige handleiding 6-12 • Betriebsanleitung Deutsch 100-240V • Instruction Manual English INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. WARNINGS AND SAFETY NOTES ......3 2. SPECIFICATIONS ........5 3.
  • Page 3: Warnings And Safety Notes

    1. WARNINGS AND SAFETY NOTES These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire. Also read the chapter before you begin. •...
  • Page 4 1. WARNINGS AND SAFETY NOTES Standard Battery Parameters Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries. Incorrect settings could cause the cells to fire or explode. Battery Fast Charge Nominal Cell Max.
  • Page 5: Specifications

    1. WARNINGS AND SAFETY NOTES Discharging The main purpose of discharging is to clean the residual capacity of the battery, or to reduce the battery’ voltage to a defined level. The same attention should be paid to the discharging process as the charging process.
  • Page 6: Charger Description

    3. CHARGER DESCRIPTION DISPLAY DEC (-) Key STOP Key COOLING FAN START/ENTER INC (+) Key Balance Port Temp Sensor Port Charging connector - XT-60 AC Input Cable included Battery Connection...
  • Page 7: Program Flow Chart

    4. PROGRAM FLOW CHART...
  • Page 8: Initial Parameter Set Up (User Setup)

    5. INITIAL PARAMETER SET UP (User Setup) When first used, the charger will display the default values on the screen. Below is the sequence in which the various programs are displayed, which you can change as required. When you wish to change the value of a parameter in the program, press the Start/ ENTER key to make it flash on the screen, then change the value with the INC (+) OR DEC (-) key.
  • Page 9 5. INITIAL PARAMETER SET UP (User Setup) Here you define the maximum temperature that the battery can reach during charge/discharge. When the battery reaches this temperature during charging, the process is interrupted to protect the battery. When the battery is in a charge/discharge cycle process, the battery may become warm.
  • Page 10: Lithium Battery (Lilo-Lipo-Life-Lihv) Program

    5. INITIAL PARAMETER SET UP (USER SETUP) Press and hold the ENTER button for 3 seconds to restore the factory default setting. Here you have the current software version number and the charger identification number. 6. LITHIUM BATTERY (LILO-LIPO-LIFE-LIHV) PROGRAM Use these programs only to charge a lithium battery ( Lilo/LiPo/LiHV/LiFe) with a nominal voltage of 3.6V, 3.7V, 3.8V or 3.3V per cell, respectively.
  • Page 11: Charging Lithium Battery (Balance Mode)

    6.1 LITHIUM BATTERY - CHARGING Here you can see the number of cells you have set up and the number of cells the processor detects. R: = the number of cells detected by the charger. S: = the number of cells that you set in the previous screen. If the two numbers are the same, you can start charging by pressing the START/ENTER button.
  • Page 12: Lithium Battery - Fast Charging

    6.3 LITHIUM BATTERY - FAST CHARGING The charging current decreases as the process nears the end of charging of lithium batteries. To complete the charging process sooner, this program eliminates certain terms from the CV process. In fact, the charging current increases to 1/5 of the initial value to complete the process while normal charging increases to 1/10 during the CV process.
  • Page 13: Lithium Battery - Discharge

    6.5 LITHIUM BATTERY - DISCHARGE The discharge current value on the left side of the display should not exceed 1C for maximum safety, the discharge cur- rent ranges from 0.1 to 2.0A and the final voltage on the right side should not be lower than the voltage level recommended by the battery manufacturer to avoid deep discharge.
  • Page 14: Nimh / Nicd - Charging

    7.1 NIMH / NICD - CHARGING This program allows you to charge the battery using the cur- rent you set. In “A” mode, you must set the upper limit of the charging current to prevent the battery from being damaged by too high a supply current.
  • Page 15: Nimh / Nicd - Cycling

    7.3 NIMH / NICD - CYCLING On the left you define the sequence and on the right the num- ber of cycles. You can use this function to balance, refresh and run-in a battery. To avoid an increase in battery temperature, there will be a short cooling period which has already been set in the “User setting”...
  • Page 16: Pb (Lead-Acid Battery) - Discharging

    8.1 Pb (LEAD-ACID BATTERY) - CHARGING The screen displays the status of the charging process. To force the charging process to stop, press the BATT TYPE/ STOP button once. The audible sound indicates the end of the process. 8.2 Pb (LEAD-ACID BATTERY) - DISCHARGING Set the charging current on the left and the final battery voltage on the right.
  • Page 17: Save / Load Data Program

    9. BATTERY INTERNAL RESISTANCE TESTING PROGRAM Press “ENTER” to access. Display the Internal Battery Resistance data. Press “INC” to check the total Internal Resistance data of the battery (press “INC” again to display the IR data of the cell). 10. SAVE / LOAD DATA PROGRAM After connecting and programming your battery, press BATT TYPE/STOP to select “PROGRAM MEMORY”...
  • Page 18: Warning And Error Messages

    11. INFORMATION DISPLAYED DURING THE PROCESS The OFF/TEMPERATURE function is activated. The switch-off temperature is displayed. The external battery temperature is displayed when the tem- perature sensor is connected. The internal temperature of the charger is displayed. When the battery is connected to the balancing port, you can check the voltage of each cell (max.4S) of the battery.
  • Page 19 12. WARNING AND ERROR MESSAGES The voltage of a cell is too low, check each cell. The voltage of a cell is too high, check each cell. Bad connection detected; check all connectors and cables. Charger temperature is too high, let the charger cool down. The processor can no longer control the supply current for any reason.
  • Page 20: Warranty Conditions & Liability Disclaimer

    RC-PLUS. There- fore RC-PLUS is in no way liable for loss, damage, or costs resulting from improper use, or behaviour in any way connected to the above described provisions. Unless otherwise required by law, RC-PLUS is in no way...
  • Page 21 This manual is protected by a copyright. Any publication, transmission or commercial use of this manual is prohibited without written permission. RC-PLUS and JSP Group Intl nv assumes no responsibility for printing errors in this manual. This manual is subject to technical changes.
  • Page 22 Declaration of Conformity RC-PLUS PLUS POWER 60 AC RC-PLUS, a division of JSP Group Intl nv declares under sole responsibility that the battery charger PLUS POWER 60 AC to which this declaration relate, conforms with the following CE- LVD standard; EN 60335-1...
  • Page 23 MEMO BATTERIES Write here your battery storage information [0] ------------------------------------------------------------------------------------------- [1] ------------------------------------------------------------------------------------------- [2] ------------------------------------------------------------------------------------------- [3] ------------------------------------------------------------------------------------------- [4] ------------------------------------------------------------------------------------------- [0] ------------------------------------------------------------------------------------------- [1] ------------------------------------------------------------------------------------------- [2] ------------------------------------------------------------------------------------------- [3] ------------------------------------------------------------------------------------------- [4] ------------------------------------------------------------------------------------------- [0] ------------------------------------------------------------------------------------------- [1] ------------------------------------------------------------------------------------------- [2] ------------------------------------------------------------------------------------------- [3] ------------------------------------------------------------------------------------------- [4] -------------------------------------------------------------------------------------------...
  • Page 24 RC PLUS is a trademark licensed to JSP GROUP INTL nv Distributed in Europe by Pro Models Distribution Geelseweg 80 • 2250 Olen • Belgium • info@rcplus.eu #RC-CHA-215-EN 413911 247467...

Table of Contents