Mitsubishi FDT100VNXWVH Service Manual page 109

Hyper inverter packaged air-conditioners
Table of Contents

Advertisement

Error code
E20
Remote control:
1. Applicable model
2. Error detection method
Detected by rotation speed of
indoor fan motor
3. Condition of error displayed
When the actual fan rotation
speed does not reach to the
speed of [required speed
(FDU : -500 min
-1
-1
-50 min
)]
after 2 minutes have been
elapsed since the fan motor
rotation speed command
was output, the unit stops by
detecting indoor fan motor
anomaly.
4. Presumable cause
• Defective indoor unit control
PCB
• Foreign material at rotational
area of fan propeller
• Defective fan motor
• Dust on indoor unit control
PCB
• Blown fuse
• External noise, surge
Note:
LED
Green
Red
Keeps flashing 1-time flash
Indoor
Keeps flashing Stays OFF
Outdoor
5. Troubleshooting
Diagnosis
Does any
foreign material
intervene in rotational area
of fan propeller?
NO
Does the fan
rotate smoothly when turned
by hand?
YES
Is DC280V
detected between Œ- of
fan motor connector
CNM?
YES
Is the fuse F2 or 3, 4 blown?
Power source reset
Is it normalized?
108
-
Content
Indoor fan motor rotation
speed anomaly
YES
NO
Note (1)  for GND
(1)
NO
NO
YES
NO
YES
-
'20 • PAC-SM-351
Countermeasure
Remove foreign material.
Replace the fan motor.
Check power voltage.
Replace faulty fan motor
and indoor unit control PCB.
Replace fan motor. (If the
error persists after replacing
the fan motor, replace the
indoor unit control PCB.)