17. A progress bar displays. The update process normally takes 1-2 minutes.
18. Once the update has finished, power off the unit by moving the battery
select switch to the "OFF" position, or by disconnecting the external battery.
19. Ensure the unit is completely discharged of electrical potential by pressing
the status button repeatedly until no LED lights flash.
20. Return the channel select dip switches to the desired channel setting.
21. Move the battery select switch to either the "Alkaline" or "Lithium" position,
according to the type of battery being used. Reconnect the external battery
if equipped.
22. Repeat the above process with all the Nodes in the Network.
The firmware update is now complete.
F.2 TROUBLESHOOTING
Make sure the green light is flashing on and off in one second intervals.
The B8800-5 multicolored update ribbon cable must be used on all units
with the exception of the RS-232 version supervisor.
Perform updates using the
adapter. Other adapters and native serial ports have been unreliable.
Make sure the batteries are fresh.
F.3 CHANGE SUMMARY FOR FIRMWARE VERSIONS
Version
(Most recent at top)
■ Prevent concurrent flash writes or erasures to protect flash integrity.
■ Verify newly-written flash metadata matches RAM master. Rewrite metadata if difference
detected.
191023
■ Load prior record into RAM during bootup if newer metadata in flash is corrupted.
■ Stop sampling supervisor every minute.
■ Update supervisor signal strength regularly.
■ Provisions GeoNet for "airplane mode", silencing radio for logger-only operation.
190807
■ Corrected fault that prevented sensemetrics threads from reading MUX boards.
190502
■ Fixes intermittent addressable discovery of drop 1
190311
■ USB lock up corrected
■ Log data from Addressable Temperature Sensors (3810A) and Addressable Vibrating Wire
Readers (8020-30).
■ Simplified keypad operation.
190125
■ Corrected defects that impeded prompt radio network connections.
■ Augmented power control and battery monitoring
■ Single Channel: VW is never disabled
181025 through
■ MUX: VW channel disabled after 10 failed reads
180228
■ MEMS: MEMS drops disabled after 10 failed reads
■ Single Channel: VW is never disabled
180213 through
170818
■ MUX: VW channel disabled after 10 failed reads
■ Single Channel: VW is disabled after 5 failed reads
Prior to 170818
■ MUX: VW is disabled after 5 failed reads

TABLE 18: Change Summary