Deployment Mode; Adding Nodes - Geokon GeoNet 8800 Series Instruction Manual

Wireless data acquistion network
Hide thumbs Also See for GeoNet 8800 Series:
Table of Contents

Advertisement

10 | NETWORK INSTALLATION | GEOKON
2.
Ensure the cover gasket and the mating ridge on the enclosure are clean,
and that the gasket is properly seated inside the groove on the cover. Place
the cover on the unit.
3.
Tighten the cover screws a little at a time, working in a diagonal pattern.
Make sure the cover seals tightly and evenly.
4.
Mount the device. The built-in mounting plate is designed to be used with
U-Bolts, hose clamps, screws, bolts, etc. Devices should be mounted
vertically, with the antenna pointing up.

2.2 DEPLOYMENT MODE

There are two modes of operation: Deployment mode and Normal mode. The
supervisor and node units all enter Deployment mode upon power up or system
reset. Perform a system reset by either pressing the blue Reset button on the
GeoNet circuit board, or by pressing and holding the Status button on the side
panel for 10 seconds.
For information on the function of the Status button, see Section 2.3.
Deployment mode allows nodes to be added to a network and verified quickly.
When the network is in Deployment mode, the network status will be indicated
by the LEDs on the supervisor every 10 seconds.
In Deployment mode, the supervisor and node units will find each other in less
than three minutes, radio circumstances permitting. Once the network has been
established and the network time has been set, the Supervisor's green LED will
flash simultaneously with the green LEDs on the nodes. If the network time has
not been set, the Supervisor's red LED will blink in unison with the nodes. The
time must then be set using the Agent software.
If the correct lights do not illuminate, or if the network has exited Deployment
mode, press the Status button on the supervisor to restart Deployment mode.

2.2.1 ADDING NODES

While in Deployment mode, nodes may be added by simply turning them on
within radio range. When adding nodes, start with those closest to the
supervisor. Place the supervisor in the center of the distribution of
nodes if possible (see Figure 16 below); doing so will reduce the number of
hops, which will reduce battery consumption.
Move nodes to their installation locations as long as the green LED is flashing.
Pay attention to the LEDs while moving the nodes to ensure the signal isn't lost.
After 10 minutes, the LEDs on the nodes will stop indicating their status in order
to conserve batteries. Pressing the Status button on a node will reactivate the
LEDs for another 10 minutes.
The default time a network will remain in Deployment mode is one hour. When a
new node joins the network the timer will reset, extending the deployment
period for another hour. If more time is needed while deploying nodes, the
default deployment timeout may be changed using Agent software.
The network will not begin collecting data until the network
time is set. To do this, use the Agent software (or other Modbus
master). The default scan interval for data collection is 10
minutes.

Advertisement

Table of Contents
loading

Table of Contents