6.4.5.5 Test the connection

After the Network Map has been configured, test the cellular connection by using the Connect
screen as shown in the following image. Click on the appropriate station and click Connect to
initiate a call to the data logger.
TIP:
The connection time is subject to many external factors. It is often less than 30 seconds but
could be up to 15 minutes. Be patient.
If the connection is successful, the connectors at the bottom of the screen will come together and
clock information from the data logger will be displayed in the Station Date/Time field. If the
connection fails, a Communications Failure message will be displayed.

7. Operation and maintenance

7.1 Ports

The CS I/O port is the main port used with Campbell Scientific data loggers. Its function is
described throughout this manual.
The RS-232 port can also be used with Campbell Scientific data loggers through a null modem
cable (or CPI/RS-232 RJ45 to DB9 cable for the CR1000X and CR6 series).
CELL200-Series 4G LTE Cellular Module
55