Huawei Tecal RH5485 Problem Determination And Service Manual page 84

Hide thumbs Also See for Tecal RH5485:
Table of Contents

Advertisement

3 Diagnostics
Numeric sensor Ambient
Temp going high (upper
critical) has deasserted.
Numeric sensor Ambient
Temp going high
non-recoverable)
has
deasserted.
Numeric sensor Planar 3.3V
going low (lower critical)
has asserted.
Numeric sensor Planar 3.3V
going high (upper critical)
has asserted.
Numeric sensor Planar 3.3V
going low (lower critical)
has deasserted.
Numeric sensor Planar 3.3V
going high (upper critical)
as deasserted.
Numeric sensor Planar 5V
going low
(lower critical) has asserted.
Numeric sensor Planar 5V
going high
(upper critical) has asserted.
Numeric sensor Planar 5V
going low
(lower critical) has
deasserted.
Numeric sensor Planar 5V
going high
(upper critical) has
deasserted.
Numeric sensor Planar 12V
going low
(lower critical) has asserted.
Numeric sensor Planar 12V
going high (upper critical)
has asserted.
3-66
Info
Info
(upper
Error
Error
Info
Info
Error
Error
Info
Info
Error
Error
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
An upper critical sensor going
high has deasserted.
An upper non-recoverable sensor
going high has deasserted.
A lower critical sensor going low
has asserted.
An upper critical sensor going
high has asserted.
A lower critical sensor going low
has deasserted.
An upper critical sensor going
high has deasserted.
A lower critical sensor going low
has asserted.
An upper critical sensor going
high has asserted.
A lower critical sensor going low
has deasserted.
An upper critical sensor going
high has deasserted.
A lower critical sensor going low
has asserted.
An upper critical sensor going
high has asserted.
Tecal RH5485 Server
Problem Determination and Service Guide
No action; information only.
No action; information only.
(Trained service technician only)
Replace the I/O-board shuttle.
(Trained service technician only)
Replace the I/O-board shuttle.
No action; information only.
No action; information only.
(Trained service technician only)
Replace the I/O-board shuttle.
(Trained service technician only)
Replace the I/O-board shuttle.
No action; information only.
No action; information only.
Check the OVER SPEC LED
(see the information about the
OVER SPEC LED in "Light path
diagnostics LEDs").
Check the OVER SPEC LED
(see the information about the
OVER SPEC LED in "Light path
diagnostics LEDs").
Issue 02 (2011-05-25)