Download Print this page
MadgeTech HiTemp150-TSK Product Information Card

MadgeTech HiTemp150-TSK Product Information Card

Extended range temperature data logger with thermal shield, extended range temperature data logger with a 24” stainless steel flexible probe and thermal shield

Advertisement

Quick Links

Description
HiTemp150-TSK
Temperature Sensor
Temperature Range
Probe Temperature Range
Temperature Resolution
Temperature Accuracy
Memory
Reading Rate
1 reading every second up to 1 reading every 12 hours
Required Interface Package
Baud Rate
Typical Battery Life
Operating Environment
–200 °C to +250 °C (Time Limited), 0 %RH to 100 %RH
Material
Dimensions: Body
Body: 1.1 in x 1.75 in dia. (28 mm x 45 mm dia.)
Dimensions: Shield
Shield: 2.1 in x 2.6 in dia. (53.34 mm x 66 mm dia.)
Probe: 2.0 in x 3/16 in dia.
Dimensions: Probe
(50 mm x 5 mm dia.)
Weight
17 oz (481.9 g)
Approvals
Time in Air to Max Internal Temp
Ambient Temperature
(150 °C/302 °F)
-200 °C (-328 °F)
-180 °C (-292 °F)
-160 °C (-256 °F)
-140 °C (-220 °F)
-120 °C (-184 °F)
-100 °C (-148 °F)
-80 °C (-112 °F)
-60 °C (-76 °F)
-40 °C to +150 °C (-40 °F to +302 °F)
160 °C (320 °F)
170 °C (338 °F)
180 °C (356 °F)
190 °C (374 °F)
200 °C (392 °F)
210 °C (410 °F)
220 °C (428 °F)
230 °C (446 °F)
240 °C (464 °F)
250 °C (482 °F)
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE
OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR
EXPLODE IF HEATED ABOVE 150 °C (302 °F).
Specifications subject to change.
See MadgeTech's terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road
Phone 603.456.2011
www.madgetech.com
HiTemp150-PT-TSK
100Ω platinum RTD
–40 °C to +250 °C
-200 ºC to +260 ºC
0.05 °C
+0.5 °C
32,767
IFC110 or IFC200
2,400
1 year
Data Logger: 316 stainless steel
Thermal Shield: Teflon
Tip: 0.125 in OD x 1.5 in L
Flexible Portion: 24 in x 0.062 in OD dia.
10.40 oz (294.84 g)
CE
Time in Liquid to Max Internal Temp
(150 °C/302 °F)
18 minutes
N/A
19 minutes
N/A
21 minutes
N/A
24 minutes
N/A
27 minutes
N/A
32 minutes
N/A
40 minutes
N/A
55 minutes
25 minutes
Indefinitely
Indefinitely
75 minutes
34 minutes
63 minutes
29 minutes
55 minutes
26 minutes
50 minutes
23 minutes
45 minutes
21 minutes
42 minutes
19 minutes
39 minutes
18 minutes
36 minutes
17 minutes
34 minutes
16 minutes
32 minutes
15 minutes
Warner, NH 03278
l
Fax 603.456.2012
l
info@madgetech.com
l
DOC-1204035-00 REV 7 2014.09.30
Product Information Card
HiTemp150-TSK
Extended Range Temperature Data Logger with Thermal Shield
HiTemp150-PT-TSK
Extended Range Temperature Data Logger with a 24"
Stainless Steel Flexible Probe and Thermal Shield
HiTemp150-TSK and
HiTemp150-PT-TSK
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at
www.madgetech.com.

Advertisement

loading

Summary of Contents for MadgeTech HiTemp150-TSK

  • Page 1 Red 485 Dark Blue Pantone 289 EXPLODE IF HEATED ABOVE 150 °C (302 °F). Light Blue 58% of Pantone 289 Specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com MadgeTech, Inc. 6 Warner Road Warner, NH 03278 Phone 603.456.2011 Fax 603.456.2012...
  • Page 2 Getting Started Manual Start”, depending upon your start method. The HiTemp150-TSK consists of a HiTemp150 data logger in a thermal enclosure and the - Disconnect the data logger from the interface cable and place it in the environment to HiTemp150-PT-TSK consists of a HiTemp150-PT data logger in a thermal enclosure. They measure.

This manual is also suitable for:

Hitemp150-pt-tsk