Remove Default Logical Unit - StorageWorks RAID Array 410 Installation Manual

For hp–ux
Hide thumbs Also See for RAID Array 410:
Table of Contents

Advertisement

Getting Started - RAID Array 410 for HP-UX
Cache condition should be GOOD
If the Cache condition is BAD then call your sales person for unit service or
replacement of the Cache module.
Battery condition should be GOOD
If the battery condition is LOW, allow the battery to charge with the subsystem power
on for at least 6 hours. The battery must be fully charged to protect the data in the
Write Back Cache. If the battery condition is still listed as LOW after 6 hours of
charging, call your sales person for unit service or replacement of the batteries.
Set the controller SCSI target number:
SWXRC> SET THIS_CONTROLLER ID=0
SWXRC> SET THIS_CONTROLLER PERFERRED_ID=0
Enter the following command to copy parameters to the other controller – the one the
terminal is not connected to:
SWXRC> SET FAILOVER COPY=THIS_CONTROLLER
SWXRC> RESTART OTHER_CONTROLLER
SWXRC> RESTART THIS CONTROLLER
Enter the following commands to verify the preceding parameters were set:
SWXRC> SHOW THIS_CONTROLLER FULL
SWXRC> SHOW OTHER_CONTROLLER FULL
2.5

Remove Default Logical Unit

The subsystem was configured at the factory with a single drive (DISK100) as a logical unit
(D0) available to the host. In order to configure the array, it is necessary to remove the
logical unit. Use the following CLI command to do so.
SWXRC> DELETE D0
2–4
The last character in the command is a zero, not the letter "oh".
NOTE
EK–SMRA3–IG. C01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAID Array 410 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents