Home >
Routine Maintenance
Clean the Corona Wire
If you have print quality problems or the control panel displays [Drum !] status, clean the corona wire.
1. Open the front cover.
2. Remove the toner cartridge and imaging unit assembly from the machine.
3. Clean the corona wire inside the imaging unit by gently sliding the tab from left to right and right to left several
times.
Be sure to return the tab to the Home position (a). The arrow on the tab must be aligned with the arrow on
the imaging unit. If it is not, printed pages may have a vertical stripe.
4. Install the toner cartridge and imaging unit assembly back into the machine.
5. Close the front cover of the machine.
Related Information
•
Clean the Machine
Related Topics:
•
Error and Maintenance Messages
>
Clean the Machine
> Clean the Corona Wire
246