7. Clean the corona wire inside the imaging unit by gently sliding the tab from left to right and right to left several
times.
Be sure to return the tab to the Home position (a). The arrow on the tab must be aligned with the arrow on
the imaging unit. If it is not, printed pages may have a vertical stripe.
8. Install the toner cartridge and imaging unit assembly back into the machine.
9. Close the front cover of the machine.
After installing the new imaging unit, you must reset the drum counter.
NOTE
•
If an unpacked imaging unit is placed in direct sunlight (or room light for long periods of time), the unit
may be damaged.
•
For best performance, use only original toner.
•
The machine should be used only in a clean, dust-free environment with adequate ventilation.
Printing with a non-genuine imaging unit may reduce not only the print quality but also the quality and life
of the machine itself. Warranty coverage does not apply to problems caused by the use of a non-genuine
imaging unit.
Related Information
•
Replace Supplies
Related Topics:
•
Error and Maintenance Messages
•
Reset the Drum Counter
241