Replacing a fan canister

Each 60-bay controller unit or 60-bay expansion unit includes two fan canisters. If a fan
canister fails, you, replace the fan canister as soon as possible to ensure that the unit has
adequate cooling.
Before you begin
About this procedure
Use this procedure to replace a fan canister in the following units:
Notice!
Possible equipment damage - If you perform this procedure with the power turned on, you
must complete it within 30 minutes to prevent the possibility of overheating the equipment.
Rear view - 60-bay controller unit (left) / 60-bay expansion unit
You can replace a fan canister while your storage array is turned on and performing host I/O
operations, as long as the following conditions are true:
Notice!
If the second fan canister in the unit does not have Optimal status or if the Recovery Guru
indicates that it is not OK to remove the fan canister, contact your technical support.
To replace a fan canister observe the instructions in the following chapters:
Bosch Security Systems B.V.
Remove the antistatic protection.
Collect support data for your storage system (see Collecting support data for the storage
system, page 50 ).
Note: Collecting support data before and after replacing a component ensures you can
send a full set of logs to technical support in case the replacement does not resolve the
problem.
Return the failed part as described in the RMA instructions shipped with the kit.
You have a replacement fan canister (fan) that is supported for your controller unit or
expansion unit model.
You have one fan canister that is installed and running.
You have an ESD wristband, or you have taken other antistatic precautions.
60-bay E2800 controller unit
60-bay E2800 expansion unit
1
1
Fan canister
The other fan canister in the unit has Optimal status.
The OK to remove field in the Details area of the Recovery Guru in SANtricity System
Manager displays Yes, indicating that it is safe to remove this component.