en | Connection
Controller A
Controller B
The Multipathing feature is enabled on dual controller units by default.
Dual controller units support 2 different cabling options for the iSCSI ports.
2020-05 | V2 | DOC
3
LN K LN K P1
0a
LN K LN K P1
0a
3
1
Management port 1 (Ethernet)
Note: Used as default.
3
Channel 3 / Controller A and
Channel 3 / Controller B (iSCSI,
optical)
5
Channel 5 / Controller A and
Channel 5 / Controller B (iSCSI, RJ45
Base‑T)
Default: iSCSI, RJ45 Base‑T
Note:
Channel 5 / Controller B is the fallback of Channel 5 / Controller A and
Channel 6 / Controller A is the fallback of Channel 6 /. Controller B
Alternatively: iSCSI, optical
Note:
Channel 3 / Controller B is the fallback of Channel 3 / Controller A and
Channel 4 / Controller A is the fallback of Channel 4 /. Controller B
Default
4
2
5
6
1
P2
0b
e0c e0d
P2
0b
e0c e0d
4
2
5
6
1
2
4
6
Installation manual
DSA E-Series (E2800 60-bay)
Alternatively
3
4
2
1
LN K LN K P1
P2
0a
0b
LN K LN K P1
P2
0a
0b
3
4
2
1
Management port 2 (Ethernet)
Note: Reserved for maintenance
operations if the hardware contains a
second Ethernet port.
Channel 4 / Controller A and
Channel 4 / Controller B (iSCSI,
optical)
Channel 6 / Controller A and
Channel 6 / Controller B (iSCSI, RJ45
Base‑T)
Bosch Security Systems B.V.
5
6
e0c e0d
e0c e0d
5
6