P a g e | 9 0
5.6 C
ONFIGURATION
PoolCop configuration menu
Pool D a ta
Set pool parameters
Volume
Enter the pool VOLUME, in cubic meters. This is used for filter duration calculations in
all automatic modes.
10m³ or less is considered a spa for filter duration calculations: hydraulic corrections
are not applied.
Flow Rate
Enter the
FLOW RATE
in m
for filter duration calculations in automatic modes:
Measure the actual hydraulic flow and enter this figure for optimum
performance; or
Use the lowest of the nominal filter rate and the nominal pump rate, less
20% as the entered flow rate.
When programming for use with a variable speed/flow pump, estimate the
average daily flow rate.
Turnovers
Set the desired
TURNOVERS
VOLUME
mode.
www.poolcop.com
M
ENU
C O N F I G U R A T I O N
Pool Data
Pump Data
Filter Data
Inputs
Factory settings
Equipment
S E L E C T
Volume
Flow Rate
Turnovers
Protect Frz
Cover Reduc
Pool Type
S E L E C T
3
/h of the hydraulic circuit with a clean filter. This is used
per day. This is used for filter duration calculations in
Q U I T
P O O L D A T A
: 60 m3
: 15 m3/h
: 2
: YES
: 30%
: Classic
Q U I T
P o o l C o p M a n u a l : V 4 2 E N
Text:
Volume
Default:
60
Entries:
1 – 250
Text:
Flow Rate
Default:
15
Entries:
1 – 99
Text:
Turnovers
Default:
2
Entries:
1 – 10
PCFR