Ca libr a t e pH
Calibrate pH to a known value
Carry out a calibration procedure for the pH sensor.
The calibration procedure is described in the MAINTENANCE MANUAL (procedure
SMU_07_EN) downloadable on our internet website
/DOWLOADS section.
During the calibration process, PoolCop compares the "offset" of the probe to the signal that would be
It is then necessary to check that the reference pH is correct. If this is the case, the probe must be replaced.
www.poolcop.com
p H C A L I B R A T I O N
Ref pH
Confirm Ref pH
SELECT to calibrate
S E L E C T
www.poolcop.com
delivered by a perfect probe. This offset is essentially related to wearing.
If the offset is too large, calibration is not possible.
:
7.00