P a g e | 1 0 2
Jetstream
Set jet stream parameters
5.6.6.2.1
Installed
If
INSTALLED: YES,
PoolCop will be able to control a Jetstream either via the
pushbutton in the pool either via a direct command.
If set to NO, the Jetstream (if any) will be operated manually.
5.6.6.2.2
Setting Command (Aux13 settings)
When Jetstream is installed,
Aux13 (Pump command) is
preconfigured in pulse mode
with
60
minutes
pulse
duration. These settings can
be changed from this view.
If the pool has a cover and the cover is detected closed by PoolCop, then the Jetstream pump is forced OFF
5.6.6.2.3
Setting push button (In9 settings)
When Jetstream is installed,
In(9)
is
preconfigured
receive
the
push
button
action. The settings can be
changed from this view.
The push button pneumatic signal must be converted into an electrical contact outside PoolCop using a
www.poolcop.com
Installed
Setting Command
Setting Pushbutton
S E L E C T
A U X 1 3 : R s r v ' d J e t S t
Mode
ON
Duration
Slave
Weekday
S E L E C T
for safety reasons. Jetstream pump is only allowed to run when the cover is not closed.
Jetstream
Action when
Alert
to
S E L E C T
pressure switch. The contact will be then connected on In(9).
J E T S T R E A M
: YES
Q U I T
: Pulse
: 00:00
: 00:60:00
: NO
✓✓✓✓✓✓✓
:
Q U I T
NOTE:
I N P U T 0 9
: Closed
: NO
Q U I T
NOTE:
P o o l C o p M a n u a l : V 4 2 E N
Text:
Installed
Default:
NO
Entries:
YES;
NO
PCFR
Need help?
Do you have a question about the Evolution and is the answer not in the manual?
Questions and answers