Foreword Documentation issue status Version Comment Chapter update: Appropriate use 1.3; For your safety 2; Product identification 3; Technical data 6 Chapter update: 5.5.1 General update First published Appropriate use The brake resistors from the AX2090-BW5x-xxxx series are exclusively designed for direct application with an AX5000 series servo drive or the AX5021 brake module.
Beckhoff Automation GmbH & Co. KG. In addition, the following actions are excluded from the liability of Beckhoff Automation GmbH & Co. • Failure to comply with this documentation •...
For your safety Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note. The safety instructions must be read carefully and followed without fail! Symbols that warn of personal injury: Serious risk of injury! This is an extremely dangerous situation.
For your safety Safety rules The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations and guidelines. Serious risk of injury through electric shock! Due to the DC link capacitors dangerous voltage (>...
Product identification Product identification Scope of supply The scope of delivery may vary depending on the ordered configuration. Before installing the device please ensure that all ordered components were delivered and that they are undamaged. In the event of any damage please contact the carrier immediately and document the damage.
Mechanical installation Mechanical installation Mounting positions and distances (A) = vertical installation is only permitted according to the diagram (terminal box facing downwards). (B) = horizontal installation Assignment of the device classes AX2090-BW51-3000 and AX2090-BW51-6000 AX2090-BW52-3000 and AX2090-BW52-6000 AX2090-BW50-xxxx AX2090-BW53-3000 and AX2090-BW53-6000 AX2090-BW51-1000 AX2090-BW54-3000 and AX2090-BW54-6000 For all mounting positions the following minimum distances must be adhered to:...
Electrical installation Electrical installation Important notes Serious risk of injury through electric shock! Only staff qualified and trained in electrical engineering are allowed to wire up the brake re- sistors. DANGER • Check the assignment of the servo drive and the brake resistor. Compare the rated voltage and the rated current of the devices.
Electrical installation Cables Beckhoff offers pre-assembled cables for safe, faster and flawless installation of the motors. Beckhoff cables have been tested with regard to the materials, shielding and connectors used. They ensure proper functioning and compliance with statutory regulations such as EMC, UL etc. The use of other cables may lead to unexpected interference and invalidate the warranty.
Electrical installation Temperature switch Destruction of the brake resistor! The temperature switch is exclusively used for temperature monitoring. The brake resistor is not switched off. Attention The temperature switch has a potential-free N/C contact, which enables immediate response to any overload of the brake resistor through analysis in the AX5000 or the PLC.
Electrical installation 5.5.2 Overload factor Calculation formula Short-term capacity = continuous power x overload factor Overtemperature and continuous power at 100% duty cycle If your application requires a higher continuous power than the specified nominal capacity, you can accept this state if a higher brake resistor temperature is permitted. The following diagram shows the overtemperature v.
Beckhoff's branch offices and representatives Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: http://www.beckhoff.com You will also find further documentation for Beckhoff components there.