Setting Up The Hdop Exceeded Caution Generation Condition - JRC JAN-7202 Instruction Manual

Conning display
Hide thumbs Also See for JAN-7202:
Table of Contents

Advertisement

Radius Limit (GPS):
The radius of a monitoring circle having the predicted position of a GPS 1 sec later at the center is
used as a threshold value. If the position actually measured is not within the time monitoring circle
specified in [Time Limit], it will be subjected to an alert. Specify the radius limit in a range between 10
and 100 m.
Radius Limit (DGPS):
The radius of a monitoring circle having the predicted position of DGPS 1 sec later at the center is used
as a threshold value. If the position actually measured is not within the time monitoring circle specified
in [Time Limit], it will be subjected to an alert. Specify the radius limit in a range between 10 and 100 m.
Time Limit:
The time during which the position actually measured by a GPS/DGPS deviates from the monitoring
circle is used as a threshold value. The time limit can be specified in a range between 1 and 29s.
6.3.2
Setting up the HDOP exceeded caution
generation condition
In the [HDOP Limit] combo box, select a threshold limit of HDOP.
Select either one of [4], [10] and [20].