  • Page 1 Instruction Manual Clinic 3.40 Compressors CLINIC 3.40 CLINIC DRY 3.40 H CLINIC DRY 3.40 HS...
  • Page 3 Instruction Manual - Clinic 3.40 Compressors INDEX INtRoDuCtIoN ....................4 StatEmENtS aND tEStINg ................... 5 Statement of delivery of the instruction manual ................5 Testing and commissioning certificate ....................6 EC DECLaRatIoN of CoNfoRmItY ..................7 StatEmENt aND CE maRk ................... 8 Statement and CE mark ........................8 gENERaLI......................
  • Page 4 Instruction Manual - Clinic 3.40 Compressors Resettable thermal ........................38 Turning off the machine ......................38 Emergency stop ..........................38 Activation after an emergency stop .....................40 Intervention of the safety valve....................40 tRoubLESHootINg ......................41 maINtENaNCE ......................42 Every week ..........................43 Every month ..........................44 AFM 30 cartridge replacement ....................
  • Page 5: Authorized Operators

    Instruction Manual - Clinic 3.40 Compressors StatEmENtS aND tEStINg StatEmENt of DELIVERY of tHE INStRuCtIoN maNuaL The employer, to the extent required by applicable law on safety and health of workers at work, hereby declares it has delivered to the authorized operators this manual for the correct information and training on use and maintenance of the machine.
  • Page 6 Instruction Manual - Clinic 3.40 Compressors tEStINg aND CommISSIoNINg DATE _________________ CERtIfICatE Designation: compressor Name: __________________________ Model:___________________________________________ Street: __________________________ Serial No:________________________________________ City: ____________________________ Manufacture year:________________________________ State: ___________________________ This is to certify that the machine in question was tested by: Test technician of the manu- facturer or authorized dealer: Mr.__________________________________________________________________________________ At the presence of the entrusted operator:...
  • Page 7: Ec Declaration Of Conformity

    Instruction Manual - Clinic 3.40 Compressors EC DECLaRatIoN of CoNfoRmItY Gentilin S.r.l. - Via delle Tezze, 20/22 36070 Trissino (VI) - Italy VAT N.: 01262520248 Declares that the following machine: CLINIC 3.40 - CLINIC DRY 3.40 H - CLINIC DRY 3.40 HS...
  • Page 8: Marking And Technical Data

    It is applied externally on one side of the machine indicated in Fig. 1 and states the fol- lowing data, in a legible manner: • LOGO, NAME AND ADDRESS OF MANUFACTURER • CE MARKING GENTILIN SRL • DESIGNATION OF THE MACHINE Via delle Tezze 20-22 36070 Trissino (VI) Italy...
  • Page 9 Instruction Manual - Clinic 3.40 Compressors gENERaL ImpoRtaNCE of tHE maNuaL Before using the machine in question, the authorized operators are obliged to read and thoroughly understand this manual in all its parts. This instruction manual has been prepared in accordance with the directions provided by the European Directives in order to ensure an easy and correct understanding of the topics covered by the authorized operators operating and maintaining the machine in question.
  • Page 10: Consultation Notes

    Instruction Manual - Clinic 3.40 Compressors CoNSuLtatIoN NotES SImboL mEaNINg Signal of generic danger: It highlights risks to health and safety of operators and/or risk of damage or malfunction of the machine. Signal of generic obligation: It indicates a requirement (obligation to take action). Generic prohibition sign: It highlights the prohibition to perform an action.
  • Page 11 Instruction Manual - Clinic 3.40 Compressors autHoRIZED opERatoRS tHE opERatoRS aRE autHoRIZED to makE oN tHE maCHINE oNLY SpE- CIfIC aCtIoNS of tHEIR CompEtENCE. THE AUTHORIZED OPERATORS, BEFORE PERFORMING ANY WORK ON THE MA- CHINE muSt bE SuRE to bE IN poSSESSIoN of fuLL pSYCHo-pHYSICaL Ca- PACITIES, SUCH AS TO ENSURE COMPLIANCE WITH THE SAFETY CONDITIONS.
  • Page 12 Instruction Manual - Clinic 3.40 Compressors ELECtRICaL maINtENaNCE tECHNICIaN It is a qualified technician (an electrician in possession of technical and professional qualifications required by the regulations), authorized to perform only work on electri- cal equipment to make adjustments, and maintenance and/or repairs, even in the presence of voltage and with the protections disabled (upon consent of the Supervisor), equipped with personal protection devices (PPD) envisioned and occupying the positions described (see related paragraph).
  • Page 13: All Rights Reserved

    Instruction Manual - Clinic 3.40 Compressors abbREVIatIoNS Lists some abbreviations used in this book. • cca. = About • cap. = Chapter • PPE = Personal protective equipment • R = Right • h = Hours • EN = European Norm •...
  • Page 14 Instruction Manual - Clinic 3.40 Compressors guaRaNtEE 1) GUARANTEE DECLARATION: the Manufacturer gives an undertaking to the End-User to repla- ce, repair or otherwise intervene in the machine, if it has conformity defects that compromise its correct use and operation, but only if such defects are attributable to the actual liability of the Manufacturer.
  • Page 15: Technical Description

    Instruction Manual - Clinic 3.40 Compressors tECHNICaL DESCRIptIoN NamE of moDELS The machine is offered in 3 models. Tab. 1 shows the model names and specifications that distinguish them. moDEL DESCRIptIoN CLINIC 3.40 • Oil-free air compressor with 40 litres tank without dryer. CLINIC DRY 3.40 H •...
  • Page 16 Instruction Manual - Clinic 3.40 Compressors NamES of paRtS In Fig. 1 are represented the major components that make up the machine. 1) Support feet 2) Non-return valve 3) Handle 4) Cooling fan protection hood 5) Two-cylinder pumping unit 6) Electric motor 7) Restorable circuit breaker 8) Electrovalve 9) Air intake filter...
  • Page 17 Instruction Manual - Clinic 3.40 Compressors CLINIC DRY 3.40 H CLINIC DRY 3.40 HS www.gentilinair.com MAN0340001 - 07/2019...
  • Page 18: Dimensions Of The Machine

    Instruction Manual - Clinic 3.40 Compressors DImENSIoNS of tHE maCHINE Tab.1 gives the clearance of the machine represented in Fig.1. CLINIC 3.40 CLINIC DRY 3.40 H Fig. 1 CLINIC DRY 3.40 HS moDELS CLINIC 3.40 653 mm 652 mm 455 mm CLINIC DRY 3.40 H 662 mm 652 mm...
  • Page 19: Technical Data

    Instruction Manual - Clinic 3.40 Compressors tECHNICaL Data maCHINE Data Tab. 2 shows the technical data which characterize the machine. CLINIC 3.40 Power supply 230V/50 Hz 230V/60 Hz 110V/60 Hz Electrical Absorption 8 amper 11 amper 22 amper Units served Air delivered (5 bar) Intake air (lt/min) Tank capacity (lt)
  • Page 20: Intended Use Of The Machine

    Instruction Manual - Clinic 3.40 Compressors INtENDED uSE of tHE maCHINE The machine was designed and built for the use described in Tab. 1. fIELD of uSE Dentistry, laboratories or dental cabinets. pLaCE of uSE Places indoors with sufficient lighting, ventilation, air environment having the characteristics referred to under par.
  • Page 21: Reasonably Foreseeable Misuse

    Instruction Manual - Clinic 3.40 Compressors pHaSES of opERatIoN In Tab. 4 are listed the steps of operation of the machine please see the relative paragraphs pHaSE opERatIoN Turning on the machine. Adjusting the outlet pressure. If requested reset the resettable thermal. Turning off the machine.
  • Page 22: Transportation And Handling

    Instruction Manual - Clinic 3.40 Compressors It IS StRICtLY pRoHIbItED to CommISSIoN tHE maCHINE IN ENVI- RoNmENtS WItH potENtIaLLY EXpLoSIVE atmoSpHERE aND/oR IN tHE PRESENCE OF COMBUSTIBLE DUSTS (E.G.: WOOD POWDER, FLOUR, SU- GARS AND GRAINS). It IS abSoLutELY foRbIDDEN to uSE tHE maCHINE IN aREaS CoNtaININg So- LID oR abRaSIVE paRtICLES.
  • Page 23 Instruction Manual - Clinic 3.40 Compressors HaNDLINg of paCkagINg WItH a foRkLIft oR tRaNSpaLLEt IT IS MANDATORY THAT, IN THE RANGE OF HANDLING OPERATIONS, THERE ARE NO PEOPLE, ANIMALS AND/OR THINGS WHOSE SAFETY CAN BE COM- pRomISED aCCIDENtaLLY. tHE HaNDLINg of tHE paCkagE CaN bE pERfoRmED oNLY bY tHE uSE of a tRaNSpaLLEt oR a foRkLIft SuItabLE foR uSE.
  • Page 24 Instruction Manual - Clinic 3.40 Compressors maNuaL HaNDLINg of tHE maCHINE tHE maNuaL HaNDLINg of tHE maCHINE muSt bE DoNE bY at LEaSt TWO OPERATORS IN CHARGE, OR USING A SUITABLE MEAN (E.G.: TRAN- SPALLET), IN ACCORDANCE WITH THE REGULATIONS ON THE “MANUAL HANDLING OF LOADS”, IN ORDER TO AVOID ADVERSE CONDITIONS THAT INVOL- VE RISk of ERgoNomIC INJuRIES to tHE baCk.
  • Page 25: Positioning Of The Machine

    Instruction Manual - Clinic 3.40 Compressors poSItIoNINg of tHE maCHINE The machine must be placed in a workplace with the characteristics described in par. “INTENDED USE OF THE MACHINE”, placed on a flat floor that ensures stability in relation to the overall dimensions and to the weight. IN oRDER to ENSuRE tHat tHE autHoRIZED opERatoRS oCCupY tHE WORK POSITIONS EXPECTED, IT IS MANDATORY TO ENSURE MINIMUM ME- aSuRES of poSItIoNINg aS SHoWN IN fIg.
  • Page 26: Installation

    Instruction Manual - Clinic 3.40 Compressors INStaLLatIoN gENERaL WaRNINgS It IS CompuLSoRY to CompLY WItH tHE CoRRECt pRoCEDuRES of aS- SEmbLY/DISaSSEmbLY aND CoNNECtIoN of CompoNENtS DESCRIbED IN tHIS CHaptER. tHE maNuaL HaNDLINg muSt bE IN CompLIaNCE WItH tHE REguLatIoNS oN tHE “maNuaL HaNDLINg of LoaDS”...
  • Page 27: Electric Connection

    Instruction Manual - Clinic 3.40 Compressors ELECtRIC CoNNECtIoN tHE maNufaCtuRER HaS No LIabILItY foR faILuRE oR maLfuNCtIoNS of opERatIoN to tHE maCHINE CauSED bY VoLtagE DRopS EXCEEDINg THE TOLERANCES PROVIDED BY THE DISTRIBUTING BODY (± 10% POWER - FREQUENCY ± 2%). tHE maINS to WHICH tHE maCHINE IS CoNNECtED muSt bE IN aCCoR- DANCE WITH THE REQUIREMENTS OF THE LAWS OF THE COUNTRY OF USE, mEEt tHE SpECIfICatIoNS CoNtaINED IN paR.
  • Page 28: Safety Devices

    Instruction Manual - Clinic 3.40 Compressors SafEtY SafEtY DEVICES The Safety Devices adopted are as follows (for the references on the drawings, please see the pages down): REf. DESCRIptIoN fuNCtIoN Cooling fan protection It is a fixed guard that consists of a grid of plastic ma- hood.
  • Page 29 Instruction Manual - Clinic 3.40 Compressors IT IS FORBIDDEN TO MANIPULATE, EXCLUDE, REMOVE AND/OR REPLACE aNY SafEtY DEVICE IN tHIS maCHINE. It IS abSoLutELY foRbIDDEN to REpLaCE aNY SafEtY DEVICE oR Compo- NENt WItH NoN oRIgINaL SpaRE paRtS. CLINIC DRY 3.40 H CLINIC 3.40 CLINIC DRY 3.40 HS www.gentilinair.com...
  • Page 30: Residual Risks

    Instruction Manual - Clinic 3.40 Compressors PERSONAL PROTECTIVE EQUIPMENT (PPD) The use of personal protective equipment (PPD) is mandatory, in accordance with the le- gislation on safety and health in the workplace regulations of the country of use of the machine.
  • Page 31: Residual Risk

    Instruction Manual - Clinic 3.40 Compressors DaNgER of CRuSHINg foot DuE to aCCIDENtaL RESIDuaL RISk N. 2 faLL fRom tHE maCHINE SEVERItY of tHE INJuRY Serious injuries usually reversible. If the operator decides to perform a voluntary improper action, EXpoSuRE forbidden and not reasonably foreseeable.
  • Page 32: Use And Operation

    Instruction Manual - Clinic 3.40 Compressors SIgN mEaNINg/pRESCRIptIoN SIgN mEaNINg/pRESCRIptIoN DANGER: Electric Current REQUIREMENT: Read the instruction manual DANGER: Automatic start REQUIREMENT: DANGER: Turn off the machine before Dangerous Temperatures carrying out maintenance uSE aND opERatIoN pLaCES oCCupIED bY autHoRIZED opERatoRS The Authorized operators, depending on the type of manual intervention required, must take the places shown in Fig.
  • Page 33: Pressure Switch

    Instruction Manual - Clinic 3.40 Compressors pRESSuRE SWItCH In Fig. 2 is represented the control device to which the authorized operator must refer for the command and control of the machine. SafEtY VaLVE Fig. 2 www.gentilinair.com MAN0340001 - 07/2019...
  • Page 34 Instruction Manual - Clinic 3.40 Compressors REf. NamE fuNCtIoN Air outlet. ¼” G hole for air connection. Tank pressure gauge. It shows the outlet air pressure set through the regulator. It is an electro-pneumatic device (set at min. 6 bar max. 8 bar) fitted onto the pneumatic plant.
  • Page 35 Instruction Manual - Clinic 3.40 Compressors CLINIC DRY 3.40 H CLINIC 3.40 CLINIC DRY 3.40 HS www.gentilinair.com MAN0340001 - 07/2019...
  • Page 36: Turning On The Machine

    Instruction Manual - Clinic 3.40 Compressors pRIoR to IgNItIoN bEfoRE tuRNINg oN tHE maCHINE tHE opERatoR IN CHaRgE muSt makE tHE CHECkS INDICatED IN tab. 1. CoNtRoL Make sure that no unauthorized persons are near the machine. Make sure the machine is properly positioned. Make sure all connections are properly made.
  • Page 37 Instruction Manual - Clinic 3.40 Compressors CLINIC DRY 3.40 H CLINIC 3.40 CLINIC DRY 3.40 HS www.gentilinair.com MAN0340001 - 07/2019...
  • Page 38: Resettable Thermal

    Instruction Manual - Clinic 3.40 Compressors RESEttabLE tHERmaL If there is an overload and/or a short circuit in the electrical system of the machine, the overload protection intervenes stopping the electric motor. The reset will occur automatically when the temperature returns within the para- meters preset by the manufacturer: 1) Set the switch (18) in pos.
  • Page 39 Instruction Manual - Clinic 3.40 Compressors CLINIC 3.40 CLINIC DRY 3.40 H CLINIC DRY 3.40 HS www.gentilinair.com MAN0340001 - 07/2019...
  • Page 40 Instruction Manual - Clinic 3.40 Compressors aCtIVatIoN aftER aN EmERgENCY Stop Only after removing the cause of the emergency and having carefully eva- luated that the decision has not caused any damage and/or problems to the machine, with the consent of the Supervisor in charge restore the ma- chine as described in the following paragraph: 1) Set the switch (18) in pos.
  • Page 41: Troubleshooting

    Instruction Manual - Clinic 3.40 Compressors tRoubLESHootINg faILuRE to foLLoW tHE pRoCEDuRES CoNtaINED IN tHIS paRagRapH maY CauSE a maLfuNCtIoN of tHE maCHINE aND/oR uNDERmINE tHE SafEtY of tHE SamE. pRobLEm CauSE SoLutIoNS The machine does No electricity. • Check that the switch (18) is in pos. not turn or stops and “ON (I)”.
  • Page 42: Maintenance

    Instruction Manual - Clinic 3.40 Compressors pRobLEm CauSE SoLutIoNS Intervention of the sa- Faulty pressure switch. fety valve. Air leak from the valve Check valve is dirty or worn. See the maintenance technicians of the pressure switch or contact an Authorized Reseller. with machine stopped.
  • Page 43: Every Week

    Instruction Manual - Clinic 3.40 Compressors EVERY WEEk At the end of the workday, run the condensate drain of the tank, following the steps below: 1) Place under the condensate drain valve, a col- lection container fit for use. 2) Slowly open the valve of condensate drain (12) and wait for a complete exit of compressed air and condensate.
  • Page 44: Every Month

    Instruction Manual - Clinic 3.40 Compressors EVERY moNtH Proceed as follows: 1) Unscrew the screw (1). 2) Remove the cover (2). 3) Remove the filter (3) and clean it with compressed air. REpLaCE tHE fILtER IN CaSE of EVIDENt WEaR. 4) After placing back the filter, replace the cover properly.
  • Page 45 Instruction Manual - Clinic 3.40 Compressors afm 30 CaRtRIDgE REpLaCEmENt • Press the lever down (A), turn of 45° the cup (B) and remove it from the cover (C). • Unscrew the filter (D). • Screw in the new filter. •...
  • Page 46: Sterile Filter Replacement

    Instruction Manual - Clinic 3.40 Compressors StERILE fILtER REpLaCEmENt • Unscrew the cover by hand (A). • Remove the filter (B). • Insert the new filter. • Screw the cover up until it reaches the mechanic stop. • Report the intervention on the maintenance sheet. www.gentilinair.com MAN0340001 - 07/2019...
  • Page 47: Extraordinary Maintenance

    Instruction Manual - Clinic 3.40 Compressors EXtRaoRDINaRY maINtENaNCE This is the set of activities designed to maintain the conditions of use and operation of the machine, through various types of intervention (adjustments, changes, etc.) performed by qualified technicians in the event of failure or wear.
  • Page 48 Instruction Manual - Clinic 3.40 Compressors SpaRE paRtS gENuINE paRtS foR aNY SubStItutIoNS muSt bE REQuIRED oNLY to tHE maNufaCtuRER. It IS StRICtLY pRoHIbItED tHE uSE of NoN oRIgINaL SpaRE paRtS. attaCHmENtS DRYER/fILtER tECHNICaL SHEEtS The following pages will give the technical sheets relative to the dryer/filter. DRYtEC tECHNICaL SHEEt The DRY TEC membrane dryer collects all of the following parts in a unique block: •...
  • Page 49 SUPPLY RATED PRESSURE: .............. 7 bar DRYER DEW POINT AT ROOM TEMPERATURE OF 25°C: ..... -19,4°C PROJECT TEMPERATURE:: ........... from +2°C to +50°C PROJECT PRESSURE: ..............max 10 bar INSTALLATION: ................internal QUALITY CONSTRUCTION CODE:: ........ISO9001:2008 GENTILIN SRL Technical dept. www.gentilinair.com MAN0340001 - 07/2019...
  • Page 50 Instruction Manual - Clinic 3.40 Compressors ETHAFILTER s.r.l. Via Dell’Artigianato, 16/18 I-36050 Sovizzo (Vicenza) Italia Tel. + 39 / 0444 376402 Fax +39 / 0444 376415 e-mail: ethafilter@ethafilter.com CERTIFICATO di CONFORMITÀ ELEMENTO FILTRANTE STERILE Modello: EDT 5635ST Questi elementi filtranti asettici sono prodotti d’altissima qualità ed assicurano il grado sterile richiesto nell’alimentazione d’aria e gas compressi.
  • Page 51 Instruction Manual - Clinic 3.40 Compressors maINtENaNCE SCHEDuLE CLINIC 3.40 Year Details Replacements Hours Date Signature 1000 1500 Date Signature 2000 2500 Date Signature 3000 3500 Date Signature G1+G2 4000 4500 Date Signature 5000 Description Q.ty/Code f2 Air intake filters spare 2×279 g1 Seal gasket kit 1×84303...
  • Page 52 Instruction Manual - Clinic 3.40 Compressors maINtENaNCE SCHEDuLE CLINIC DRY 3.40 H / CLINIC DRY 3.40 HS Year Details Replacements Hours Date Signature 1000 1500 Date Signature 2000 2500 Date Signature 3000 3500 Date Signature G1+G2 4000 4500 Date Signature 5000 Description Q.ty/Code...