  • Page 1 All manuals and user guides at all-guides.com Instruction Manual Compressors CLINIC 1.25 CLINIC DRY 1.25 CLINIC 3.25 CLINIC DRY 3.25...
  • Page 2 All manuals and user guides at all-guides.com...
  • Page 3 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic INDEX INtRoDuCtIoN ....................4 statEmENts aND tEstINg ................... 5 Statement of delivery of the instruction manual ................5 Testing and commissioning certificate ....................6 EC DECLaRatIoN of CoNfoRmItY ..................7 statEmENt aND CE maRk ...................
  • Page 4 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic Resettable thermal ........................38 Turning off the machine ......................38 Emergency stop ..........................38 Activation after an emergency stop .....................40 Intervention of the safety valve....................40 tRoubLEshootINg ......................41 maINtENaNCE ......................42 Every week ..........................43 Every month ..........................
  • Page 5 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic statEmENts aND tEstINg statEmENt of DELIVERY of thE INstRuCtIoN maNuaL The employer, to the extent required by applicable law on safety and health of workers at work, hereby declares it has delivered to the authorized operators this manual for the correct information and training on use and maintenance of the machine.
  • Page 6: Testing And Commissioning

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic tEstINg aND CommIssIoNINg DATE _________________ CERtIfICatE Designation: compressor Name: __________________________ Model:___________________________________________ Street: __________________________ Serial No:________________________________________ City: ____________________________ Manufacture year:________________________________ State: ___________________________ This is to certify that the machine in question was tested by: Test technician of the manu- facturer or authorized dealer: Mr.__________________________________________________________________________________ At the presence of the entrusted operator:...
  • Page 7: Ec Declaration Of Conformity

    Gentilin S.r.l. - Via delle Tezze, 20/22 36070 Trissino (VI) - Italy VAT N.: 01262520248 Declares that the following machine: CLINIC 1.25 - CLINIC DRY 1.25 - CLINIC 3.25 - CLINIC DRY 3.25 Machine: Air volumetric compressor Serial Number: ___________________________________________...
  • Page 8: Marking And Technical Data

    • MAX. WORKING PRESSURE (bar) • VOLTAGE (V / Hz / A) • SHAFT ROTATION SPEED (rpm) • RATED POWER (kW) • WEIGHT (kg) GENTILIN SRL Via delle Tezze 20-22 36070 Trissino (VI) Italy phone +39 0445 96 2000 info@gentilinair.com ......
  • Page 9: Importance Of The Manual

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic gENERaL ImpoRtaNCE of thE maNuaL Before using the machine in question, the authorized operators are obliged to read and thoroughly understand this manual in all its parts. This instruction manual has been prepared in accordance with the directions provided by the European Directives in order to ensure an easy and correct understanding of the topics covered by the authorized operators operating and maintaining the machine in question.
  • Page 10 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic CoNsuLtatIoN NotEs sImboL mEaNINg Signal of generic danger: It highlights risks to health and safety of operators and/or risk of damage or malfunction of the machine. Signal of generic obligation: It indicates a requirement (obligation to take action).
  • Page 11: Authorized Operators

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic authoRIZED opERatoRs thE opERatoRs aRE authoRIZED to makE oN thE maChINE oNLY spE- CIfIC aCtIoNs of thEIR CompEtENCE. THE AUTHORIZED OPERATORS, BEFORE PERFORMING ANY WORK ON THE MA- ChINE must bE suRE to bE IN possEssIoN of fuLL psYCho-phYsICaL Ca- PACITIES, SUCH AS TO ENSURE COMPLIANCE WITH THE SAFETY CONDITIONS.
  • Page 12 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic ELECtRICaL maINtENaNCE tEChNICIaN It is a qualified technician (an electrician in possession of technical and professional qualifications required by the regulations), authorized to perform only work on electri- cal equipment to make adjustments, and maintenance and/or repairs, even in the presence of voltage and with the protections disabled (upon consent of the Supervisor), equipped with personal protection devices (PPD) envisioned and occupying the positions...
  • Page 13: All Rights Reserved

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic abbREVIatIoNs Lists some abbreviations used in this book. • cca. = About • cap. = Chapter • PPE = Personal protective equipment • R = Right • h = Hours •...
  • Page 14 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic guaRaNtEE 1) GUARANTEE DECLARATION: the Manufacturer gives an undertaking to the End-User to repla- ce, repair or otherwise intervene in the machine, if it has conformity defects that compromise its correct use and operation, but only if such defects are attributable to the actual liability of the Manufacturer.
  • Page 15: Technical Description

    The machine is offered in eight models. Tab. 1 shows the model names and specifications that distinguish them. moDEL DEsCRIptIoN CLINIC 1.25 • Oil-free air compressor with 25 litres tank without dryer. CLINIC DRY 1.25 • Oil free air compressor with 25 litres tank with silica salt dryer.
  • Page 16: Names Of Parts

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic NamEs of paRts In figures are represented the major components that make up the machine. CLINIC 1.25 1) Support feet 2) Non-return valve 3) Single cylinder pumping unit...
  • Page 17 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic CLINIC 3.25 CLINIC DRY 3.25 www.gentilinair.com MAN1325001 - 07/2019...
  • Page 18: Dimensions Of The Machine

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic DImENsIoNs of thE maChINE Tab.1 gives the clearance of the machine represented in Fig.1. CLINIC 1.25 CLINIC DRY 1.25 CLINIC 3.25 CLINIC DRY 3.25 Fig. 1 moDELs CLINIC 1.25...
  • Page 19: Technical Data

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic tEChNICaL Data maChINE Data Tab. 2 shows the technical data which characterize the machine. CLINIC 1.25 Power supply 230V/50 Hz 230V/60 Hz 110V/60 Hz Electrical Absorption 6 amper...
  • Page 20 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic CLINIC 3.25 Power supply 230V/50 Hz 230V/60 Hz 110V/60 Hz Electrical Absorption 8,1 amper 11 amper 22 amper Units served Air delivered (5 bar) (liters/min) Intake air (liters/min) Tank capacity (liters) Motor power (Watt) 1800...
  • Page 21: Intended Use Of The Machine

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic INtENDED usE of thE maChINE The machine was designed and built for the use described in Tab. 1. fIELD of usE Dentistry, laboratories or dental cabinets. pLaCE of usE Places indoors with sufficient lighting, ventilation, air environment having the characteristics referred to under par.
  • Page 22: Phases Of Operation

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic phasEs of opERatIoN In Tab. 4 are listed the steps of operation of the machine please see the relative paragraphs phasE opERatIoN Turning on the machine. Adjusting the outlet pressure. If requested reset the resettable thermal.
  • Page 23 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic It Is stRICtLY pRohIbItED to CommIssIoN thE maChINE IN ENVI- RoNmENts WIth potENtIaLLY EXpLosIVE atmosphERE aND/oR IN thE PRESENCE OF COMBUSTIBLE DUSTS (E.G.: WOOD POWDER, FLOUR, SU- GARS AND GRAINS). It Is absoLutELY foRbIDDEN to usE thE maChINE IN aREas CoNtaININg so- LID oR abRasIVE paRtICLEs.
  • Page 24 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic haNDLINg of paCkagINg WIth a foRkLIft oR tRaNspaLLEt IT IS MANDATORY THAT, IN THE RANGE OF HANDLING OPERATIONS, THERE ARE NO PEOPLE, ANIMALS AND/OR THINGS WHOSE SAFETY CAN BE COM- pRomIsED aCCIDENtaLLY.
  • Page 25 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic maNuaL haNDLINg of thE maChINE thE maNuaL haNDLINg of thE maChINE must bE DoNE bY at LEast TWO OPERATORS IN CHARGE, OR USING A SUITABLE MEAN (E.G.: TRAN- SPALLET), IN ACCORDANCE WITH THE REGULATIONS ON THE “MANUAL HANDLING OF LOADS”, IN ORDER TO AVOID ADVERSE CONDITIONS THAT INVOL- VE RIsk of ERgoNomIC INJuRIEs to thE baCk.
  • Page 26: Positioning Of The Machine

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic posItIoNINg of thE maChINE The machine must be placed in a workplace with the characteristics described in par. “INTENDED USE OF THE MACHINE”, placed on a flat floor that ensures stability in relation to the overall dimensions and to the weight.
  • Page 27: Installation

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic INstaLLatIoN gENERaL WaRNINgs It Is CompuLsoRY to CompLY WIth thE CoRRECt pRoCEDuREs of as- sEmbLY/DIsassEmbLY aND CoNNECtIoN of CompoNENts DEsCRIbED IN thIs ChaptER. thE maNuaL haNDLINg must bE IN CompLIaNCE WIth thE REguLatIoNs oN thE “maNuaL haNDLINg of LoaDs”...
  • Page 28: Electric Connection

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic ELECtRIC CoNNECtIoN thE maNufaCtuRER has No LIabILItY foR faILuRE oR maLfuNCtIoNs of opERatIoN to thE maChINE CausED bY VoLtagE DRops EXCEEDINg THE TOLERANCES PROVIDED BY THE DISTRIBUTING BODY (± 10% POWER - FREQUENCY ±...
  • Page 29: Safety Devices

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic safEtY safEtY DEVICEs The Safety Devices adopted are as follows (for the references on the drawings, please see the pages down): REf. DEsCRIptIoN fuNCtIoN Resettable thermal. It is a thermal protection installed on the electrical sy- stem, which stops the electric motor in case of current overload and/or short circuit.
  • Page 30 CLINIC DRY 1.25 EXCLUDE, REMOVE AND/OR REPLA- CE aNY safEtY DEVICE IN thIs maChINE. It Is absoLutELY foRbIDDEN to REpLa- CE aNY safEtY DEVICE oR CompoNENt WIth NoN oRIgINaL spaRE paRts. CLINIC 1.25 CLINIC 3.25 CLINIC DRY 3.25 www.gentilinair.com MAN1325001 - 07/2019...
  • Page 31: Residual Risks

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic PERSONAL PROTECTIVE EQUIPMENT (PPD) The use of personal protective equipment (PPD) is mandatory, in accordance with the le- gislation on safety and health in the workplace regulations of the country of use of the machine.
  • Page 32: Safety Signs

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic DaNgER of CRushINg foot DuE to aCCIDENtaL REsIDuaL RIsk N. 2 faLL fRom thE maChINE sEVERItY of thE INJuRY Serious injuries usually reversible. If the operator decides to perform a voluntary improper action, EXposuRE forbidden and not reasonably foreseeable.
  • Page 33 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic sIgN mEaNINg/pREsCRIptIoN sIgN mEaNINg/pREsCRIptIoN DANGER: Electric Current REQUIREMENT: Read the instruction manual DANGER: Automatic start REQUIREMENT: DANGER: Turn off the machine before Dangerous Temperatures carrying out maintenance usE aND opERatIoN pLaCEs oCCupIED bY authoRIZED opERatoRs The Authorized operators, depending on the type of manual intervention required, must take the places shown in Fig.
  • Page 34: Pressure Switch

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic pREssuRE sWItCh In Fig. 2 is represented the control device to which the authorized operator must refer for the com- mand and control of the machine. Fig. 2 safEtY VaLVE REf.
  • Page 35 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic CLINIC 1.25 CLINIC DRY 1.25 CLINIC 3.25 CLINIC DRY 3.25 www.gentilinair.com MAN1325001 - 07/2019...
  • Page 36: Turning On The Machine

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic pRIoR to IgNItIoN bEfoRE tuRNINg oN thE maChINE thE opERatoR IN ChaRgE must makE thE ChECks INDICatED IN tab. 1. CoNtRoL Make sure that no unauthorized persons are near the machine. Make sure the machine is properly positioned.
  • Page 37: Resettable Thermal

    3) Before restarting the machine wait a few minutes. IF AFTER PERFORMING THE RESET THE MACHINE WILL NOT RESTART, THE opERatoR Is REQuIRED to obtaIN thE INtERVENtIoN of maINtENaNCE tEChNICIaNs aND/oR thE authoRIZED DEaLER. CLINIC 1.25 CLINIC 3.25 CLINIC DRY1.25 CLINIC DRY 3.25 www.gentilinair.com...
  • Page 38: Turning Off The Machine

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic tuRNINg off thE maChINE At the end of the work cycle perform the turning off of the machine as fol- lows: 1) Set the switch (14) in pos. “OFF (0)”. 2) Unplug the power cord (11) from the socket and place it next to the machine.
  • Page 39 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic aCtIVatIoN aftER aN EmERgENCY stop Only after removing the cause of the emergency and having carefully eva- luated that the decision has not caused any damage and/or problems to the machine, with the consent of the Supervisor in charge restore the ma- chine as described in the following paragraph: 1) Set the switch (14) in pos.
  • Page 40: Troubleshooting

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic tRoubLEshootINg faILuRE to foLLoW thE pRoCEDuREs CoNtaINED IN thIs paRagRaph maY CausE a maLfuNCtIoN of thE maChINE aND/oR uNDERmINE thE safEtY of thE samE. pRobLEm CausE soLutIoNs The machine does No electricity.
  • Page 41: Maintenance

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic pRobLEm CausE soLutIoNs Intervention of the sa- Faulty pressure switch. fety valve. Air leak from the valve Check valve is dirty or worn. See the maintenance technicians of the pressure switch or contact an Authorized Reseller.
  • Page 42 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic EVERY WEEk At the end of the workday, run the condensate drain of the tank, following the steps below: 1) Place under the condensate drain valve, a col- lection container fit for use.
  • Page 43: Every Month

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic EVERY moNth Proceed as follows: 1) Unscrew the screw (1). 2) Remove the cover (2). 3) Remove the filter (3) and clean it with compressed air. REpLaCE thE fILtER IN CasE of EVIDENt WEaR. 4) After placing back the filter, replace the cover properly.
  • Page 44 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic DRYER fILtER EsC.f1 maINtENaNCE EVERY 1000 houRs oR EVERY 12 moNths • Replacement of PELLETS – REGENERATING KIT (COD. 84213) • Unscrew the dryer from the beam (17). •...
  • Page 45 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic DRYER fILtER EsC.f3 maINtENaNCE EVERY 1000 houRs oR EVERY 12 moNths • Replacement of PELLETS – REGENERATING KIT (COD. 84213) • Unscrew the dryer from the beam (17). •...
  • Page 46: Extraordinary Maintenance

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic EXtRaoRDINaRY maINtENaNCE This is the set of activities designed to maintain the conditions of use and operation of the machine, through various types of intervention (adjustments, changes, etc.) performed by qualified technicians in the event of failure or wear.
  • Page 47: Spare Parts

    All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic spaRE paRts gENuINE paRts foR aNY substItutIoNs must bE REQuIRED oNLY to thE maNufaCtuRER. It Is stRICtLY pRohIbItED thE usE of NoN oRIgINaL spaRE paRts. www.gentilinair.com MAN1325001 - 07/2019...
  • Page 48 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic maINtENaNCE sChEDuLE CLINIC 1.25 Year Details Replacements Hours Date Signature 1000 1500 Date Signature 2000 2500 Date Signature 3000 3500 Date Signature 4000 4500 Date Signature 5000 Description Q.ty/Code...
  • Page 49 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic maINtENaNCE sChEDuLE CLINIC DRY 1.25 Year Details Replacements Hours Date Signature 1000 1500 Date Signature 2000 2500 Date Signature 3000 3500 Date Signature 4000 4500 Date Signature 5000 Description Q.ty/Code f2 Air intake filters spare...
  • Page 50 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic maINtENaNCE sChEDuLE CLINIC 3.25 Year Details Replacements Hours Date Signature 1000 1500 Date Signature 2000 2500 Date Signature 3000 3500 Date Signature G1+G2 4000 4500 Date Signature 5000 Description Q.ty/Code f2 Air intake filters spare...
  • Page 51 All manuals and user guides at all-guides.com Instruction Manual - Compressors Clinic maINtENaNCE sChEDuLE CLINIC DRY 3.25 Year Details Replacements Hours Date Signature 1000 1500 Date Signature 2000 2500 Date Signature 3000 3500 Date Signature G1+G2 4000 4500 Date Signature 5000 Description Q.ty/Code...
  • Page 52 All manuals and user guides at all-guides.com Via delle Tezze, 20/22 36070 TRISSINO (VI) Italy phone +39 0445 96 20 00 Nuovo Manuale per Compressori Serie 1-25 - 3-25 info@gentilinair.com www.gentilinair.com M A N 1 3 2 5 0 0 1...

This manual is also suitable for:

Clinic dry 1.25Clinic 3.25Clinic dry 3.25

Table of Contents